Sony CMD-J5/J16 specifications Battery Charging, Battery Safety, Battery Capacity

Page 6

2.5 Battery Charging

There is no charging circuitry in the battery pack. The CMD-J5/J16 has complete charger function internally.

The telephone can be charged only with the battery connected the phone. This situation can be sub-divided into two situations: the phone is on or off. It can be charged with the AC Adapter, Travel Charger or Cigar Lighter Charger.

The battery symbol is used to indicate the charging, and to indicate when the battery is fully charged. This is done using the following sequence of icons:

The uncharged segments of the battery are moving in a right to left manner until the charging stops. The sequences for each charging level is repeated until the battery is charged to that level.

When the charging sequence is finished the flashing of the battery level sign stops.

The phone shows the full-battery icon.

2.6 Battery Safety

The battery pack contains a single Li-ion cell, a safety circuitry and, in addition, a microprocessor unit which manages RTC information by reading out the binary counter value in the microprocessor. The charging circuitry and the safety circuitry together guarantee a double fail-safe battery pack. This means that each component can be either short or open and still all the safety requirements will not be violated.

The safety concept protects against:

Over voltage: The charging is stopped when Battery Voltage (Vbat) reaches 4.25V- 4.3V. The charging resumes when Vbat falls below (4.025V - 4.125V).

Under voltage: When the cell voltage drops below 2.242V – 2.358V the cell is disconnected for discharging. Charging is still possible.

Current fuse: Finally, if all protection functions are out of order due to abnormal condition, the current fuse protects the device from explosion and fire with melting. The fuse melts 10A during 1 second.

2.7 Battery Capacity:

Standard Battery 640mAh typical Li-ion QN-J5BPS

Extended Battery 920mAh typical Li-ion QN-J5BPE

The phone can be charged even during making phone calls.

However, the shortest charging time will be reached when the phone is switched off.

6

Image 6
Contents CMD-J5/J16 ESD Handling precautions Table of Contents Section General Descriptions Multi-bandDCS Languages Radio Frequency Power LevelsSpeech Codec Preferences GSMBattery Charging Battery SafetyBattery Capacity Accessory Interface Connector layoutParts and Controls Basic Features of the CMD-J5/J16Section Operating Instructions Jog DialCentre Key Side SwitchSecurity Codes Voicemail KeyIcon Glossary Menu OverviewSection Disassembling / Testing DisassemblyCabinet Lower Do not detach the shield case from the main boardCMD- J 5/J Battery Pack Test SIM Card Service Test Connector Interface to GSM-TesterLevel Test Procedure with GSM Tester recommendation Jigs & ToolsHardware set-up Programming InstructionsRequirement Software set-up− The default values are 2 ∗ Save Personal Data in Mobile Get Data / Write DataGeneral RF Indications Section DiagramsBlock Diagram Radio Frequency RF TransmitterBlock Diagram Baseband General Baseband IndicationsGeneral Audio Indications Block Diagram AudioHeadset Connector Headphone Jack Multiactor Loudspeaker /Ringer VibratorSection Spare Parts and Accessories List Sony Corporation