Gemini PT-1000 II manual Introduction, Features, Precautions, Parts Checklist, Assembly and Set-Up

Page 4

Introduction

Congratulations on purchasing a Gemini PT-1000 II high-torque direct drive professional turntable. This state of the art turntable includes the latest features in modern direct drive turntable technology. Prior to use, we suggest that you carefully read all the instructions.

Features

Quartz locked speed

+/- 10% Pitch control

Fully electronic braking

Strobe illuminator

Soft-touch start/stop switch

Platter Reverse

Precautions

1. Read all operating instructions before using this equipment.

2. To reduce the risk of electrical shock, do not open the unit. There are NO USER REPLACEABLE PARTS INSIDE. Please contact the Gemini Service Department or your authorized dealer to speak to a qualified service technician.

In the U.S.A., if you have any problems with this unit, call 1-732-738-9003 for customer service. Do not return equipment to your dealer.

3.Tone arm bearings are factory set and sealed. Any attempt at adjustment will void the warranty.

4.Be sure that all AC power is OFF while making connections.

5.Cables should be low capacitance, shielded and of proper length. Make sure that all plugs and jacks are tight and properly connected.

6.Always begin with the audio level faders/volume controls set at minimum and the speaker volume control(s) set to OFF. Wait 8 to 10 seconds prior to turning up the speaker volume to prevent the transient “POP” that could result in speaker/crossover damage.

7.DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE.

8.DO NOT USE ANY SPRAY CLEANER OR LUBRICANT ON ANY CONTROLS OR SWITCHES.

Parts Checklist

 

Turntable unit

1

Dust cover hinge

2

Turntable platter

1

45 RPM adapter

1

Neoprene mat

1

Counter balance

1

Dust cover

1

Headshell

1

Assembly and Set-Up

 

3.After checking to ensure that all packing materials have been removed, gently place the PLATTER (2) on the center spindle of the TURNTABLE BASE (1).

4.Put the NEOPRENE MAT (4) on the PLATTER (2).

CARTRIDGE INSTALLATION: (SEE FIG. 2)

Because all cartridges have their own designs, please refer to your particular cartridge’s instructions to insure proper installation.

1.Connect the lead wires to the cartridge terminals. For your convenience, the terminals of most cartridges are color coded. Connect each lead wire to the terminal of the same color.

White (L+)

Left Channel +

Blue (L-)

Left Channel -

Red (R+)

Right Channel +

Green (R-)

Right Channel -

2.Mount the cartridge in the HEADSHELL (5) and tighten it with the screws included with the cartridge.

ATTENTION STANTON 680 CARTRIDGE USERS

When using a Stanton 680 or similar cartridge, where the body is grounded to a cartridge terminal, remove the grounding strap from the cartridge body to the cartridge ground terminal. Failure to do this may result in excessive hum.

HEADSHELL INSTALLATION:

Insert the HEADSHELL (5) into the front of the tubular TONE ARM (6). While holding the HEADSHELL firmly in a horizontal position, turn the LOCKING NUT (7) counter clockwise until the HEADSHELL is locked in place.

COUNTERWEIGHT INSTALLATION: (SEE FIG. 3)

1.Slide the COUNTERWEIGHT (8) onto the rear of the TONE ARM (6) with the numbered stylus gauge facing forward.

2.Twist the COUNTERWEIGHT (8) lightly counter clockwise, to screw it onto the rear of the TONE ARM (6).

ADJUSTING HORIZONTAL ZERO (0) BALANCE AND STYLUS PRESSURE:

1.Without touching the stylus tip, remove the stylus protector (if your cartridge has a detachable one).

2.Release the ARM CLAMP (9) and lift the TONE ARM (6) off the ARM REST (10).

3.Counter clockwise advancement of the COUNTERWEIGHT (8) will cause the cartridge side of the TONE ARM (6) to be lowered. Clockwise will cause the opposite. Turn the COUNTERWEIGHT clockwise or counter clockwise as needed until the TONE ARM is balanced horizon- tally. You can easily tell this by watching for the point where the TONE ARM “floats” freely.

4.Place TONE ARM (6) on ARM REST (10) and lock it in place with the ARM CLAMP (9).

5.With the TONE ARM (6) locked on the ARM REST (10), hold the COUNTERWEIGHT (8) steady with one hand while rotating the STYLUS PRESSURE RING (11) until the numeral “0” on the ring aligns with the center line on the TONE ARM (6) rear shaft. The horizontal zero (0) balance should be completed.

NOTE: SEE FIG. 1 (PAGE 1) FOR PART NUMBERS AND LOCATIONS.

TURNTABLE INSTALLATION:

1.Set the TURNTABLE BASE (1) on a flat, level surface free of vibration. Try to place the unit as far away from the speakers as possible. Keep the unit away from direct exposure to the sun, heat, moisture or dirt. Keep the unit well ventilated. Use the turntable feet to horizontally stabilize the unit.

2.Make sure that the VOLTAGE SELECTOR (3) switch (located on the TURNTABLE BASE) is set to the correct voltage. WARNING: If you try to operate the turntable with the incorrect voltage setting, it can damage your turntable.

6.Refloat the TONE ARM to ensure horizontal zero (0) balance. If zero balance has not been maintained, repeat counterweight steps 3 - 5.

7.After adjusting the horizontal zero (0) balance, turn the balanced COUNTERWEIGHT (8) counter clockwise until the cartridge manufacturer’s recommend stylus pressure appears on the STYLUS PRESSURE RING (11) where it meets the center line of the TONE ARM

(6) rear shaft.

ADJUSTING THE ANTI-SKATING CONTROL:

Set the ANTI-SKATING CONTROL (12) to the same value as the stylus pressure.

Page 4

Image 4
Contents PT-1000 Page Page Features PrecautionsParts Checklist Assembly and Set-UpOperating Instructions Specifications Turntable SectionTonearm Section GeneralEinleitung LeistungsmerkmaleVorsichtsmaßnahmen Teile-LieferumfangBedienungsanweisungen Pitch BEND-TASTEN SpezifikationenRegulierung DER Armlifthöhe Montaje y configuración IntroducciónCaracterísticas PrecaucionesInstrucciones de operación Especificaciones Ajuste DE Altura DEL AlzabrazoSección DE Tocadisco Sección DE Brazo DE FonocaptorMontage et configuration CaractéristiquesPrécautions Liste des piècesMode d’emploi Pitch Bend Buttons Touches DE Rattrapage Caractéristiques TechniquesReglage DE LA Hauteur DE Montee DU Bras Introduzione Caratteristiche principaliPrecauzioni Lista dei componentiIstruzioni per il funzionamento Specifiche Tecniche Regolazione DELL’ELEVAZIONE DEL BraccioGiradischi BraccioDo not attempt to return this equipment to your dealer

PT-1000 II specifications

The Gemini PT-1000 II is a state-of-the-art testing and measurement device that has garnered attention in various industries for its precision and reliability. Designed to meet the rigorous demands of both professionals and enthusiasts, the PT-1000 II boasts a variety of features and technologies that enhance its performance and usability.

One of the main features of the Gemini PT-1000 II is its high-resolution LCD screen, which provides clear and easy-to-read data outputs. This display is coupled with an intuitive user interface, making it simple for users to navigate through its array of functionalities. This user-friendly design ensures that both novices and experts can efficiently operate the device.

The device supports multiple measurement modes, allowing users to perform tests with a high degree of accuracy. This versatility makes it suitable for applications in fields such as electronics, automotive, and HVAC. Furthermore, the PT-1000 II is capable of conducting both analog and digital signal tests, broadening its functionality.

Another remarkable characteristic of the Gemini PT-1000 II is its integration of advanced data logging capabilities. This feature allows users to record measurement results over time, making it an ideal tool for monitoring changes in various parameters. The device can store a significant amount of data, which can later be reviewed or exported for analysis.

In terms of connectivity, the PT-1000 II is equipped with USB and Bluetooth options. This connectivity ensures seamless integration with PCs and other smart devices, enabling users to transfer data quickly and easily. The ability to connect wirelessly adds convenience, especially for fieldwork, where mobility is crucial.

Moreover, the Gemini PT-1000 II utilizes innovative sensor technology, ensuring high accuracy and minimal error margins during measurements. The sensors are designed to operate efficiently across a wide range of temperatures and environments, which enhances reliability in diverse conditions.

With its robust construction, the PT-1000 II is built to withstand the rigors of demanding work environments. The device features a rugged design that is resistant to dust, moisture, and other potential hazards, making it ideal for outdoor use.

In summary, the Gemini PT-1000 II stands out as a leading testing device characterized by its high-quality display, versatile measurement capabilities, advanced data logging, effective connectivity options, innovative sensor technology, and rugged build. Whether for professional, industrial, or personal use, the PT-1000 II is engineered to deliver exceptional performance and reliability in a compact and user-friendly package.