Gemini PT-1000 II manual Operating Instructions

Page 5

INSTALLING THE DUSTCOVER:

1.Mount the hinges onto the dustcover.

2.Hold the dustcover in position, directly above the turntable, and slide the hinge bases into the holders mounted on the rear panel.

3.Always raise the dustcover before removal.

4.Avoid opening and closing the dustcover during play. Undesirable vibration and stylus skipping can result.

TARGETLIGHT:

1.Push the TARGET LIGHT SWITCH (18) firmly and the TARGET LIGHT

(19)will raise into position and illuminate the stylus tip.

2.To lower the TARGET LIGHT, push down on it until it locks in the casing.

3.When not being used, the TARGET LIGHT should be kept in the lowered position.

CONNECTIONS:

1.Plug the AC power plug into an appropriate outlet.

2.See Table A for proper connection of the output RCA plugs and ground connector. Make sure that all the plugs are firmly plugged into the appropriate jacks (phono inputs). To reduce hum, make sure the ground lug is firmly connected to the ground screw.

TABLE A

OUTPUT CONNECTORS

MIXER OR

 

RECEIVER

 

 

L (WHITE)

PHONO L CHANNEL

 

 

R (RED)

PHONO R CHANNEL

 

 

GND (Spade Lug)

GND Screw

 

 

Operating Instructions

BASIC OPERATION:

1.Place a record on the NEOPRENE MAT (4) which sits on the PLATTER (2).

2.Select the desired speed by depressing the 33 or 45 SPEED SELECTOR (15) button.

3.Turn the POWER (13) switch to the “ON” position, at which point the strobe illuminator (built into the POWER switch and the speed indicator (for the selected speed) will illuminate.

4.Remove the stylus protector (if applicable to your cartridge).

5.Release the ARM CLAMP (9) found on the ARM REST (10).

6.Push the START STOP (14) button. The turntable PLATTER (2) will start to spin.

7.Push the CUE LEVER (16) to the “UP” position.

8.Position the tone arm over the desired position on the record and push the CUE LEVER to the “DOWN” position. The TONE ARM (6) will slowly lower onto the record at which time play will begin.

9.When play is over, raise the TONE ARM (6), move it to the ARM REST

(10), and secure it with the ARM CLAMP (9).

10.You now have the option of turning off the power by turning the POWER

(13)switch to the “OFF” position, or stopping the PLATTER (2) by pushing the START STOP (14) button and engaging the electronic brake.

INTERRUPTING PLAY:

1.Pushing the CUE LEVER (16) to the “UP” position will cause the TONE ARM (6) to lift, stopping play.

2.Pushing the CUE LEVER to the “DOWN” position will cause the TONE ARM to slowly lower onto the record at the point where play was interrupted.

PLAYING 45 RPM RECORDS:

1.When playing a 45 RPM record with a large center hole, first place the 45 ADAPTER (17) on the center spindle.

2.Be sure that the 45 SPEED SELECTOR (15) button is pushed and the 45 speed indicator is illuminated.

ADJUSTING THE PITCH CONTROL:

1.The PT-1000 II is equipped with PITCH CONTROL (21) and QUARTZ LOCK (23). When the QUARTZ LOCK is activated, the QUARTZ LOCK LED (22) lights GREEN, and the speed will be exactly 33 1/3 or 45 RPM depending on which SPEED SELECTOR (15) button is pushed regardless of the position of the pitch control. PITCH CONTROL automatically disengages when QUARTZ LOCK is activated.

2.When the QUARTZ LOCK is off, you can adjust the PITCH CONTROL. When you move PITCH CONTROL off center, the pitch can vary +/- 10% depending on the position of the PITCH CONTROL.

3.Push the QUARTZ LOCK (23) button to bring the speed back to exactly 33 1/3 or 45 RPM when the PITCH CONTROL is positioned off center. Disengaging the QUARTZ LOCK will bring the platter speed back to the original pitch setting.

4.The PLATTER (2) is equipped with a STROBE RPM INDICATOR STRIP (24) and the POWER (13) switch contains built in STROBE LIGHTS (25). When the PLATTER (2) is spinning, the STROBE LIGHTS illuminate the STROBE RPM INDICATOR STRIP. The bottom row of dots will appear to be stationary when the pitch is -3.3%. The second row of dots from the bottom will appear to be stationary when the speed is exactly 33 1/3 or 45 RPM depending on which SPEED SELECTOR (15) button is pushed. The third row of dots from the bottom will appear to be stationary when the pitch is +3.3%. The top row of dots will appear to be stationary when the pitch is +7.2%.

PITCH BEND:

1.Pushing the PITCH BEND (20) buttons will temporarily raise or lower the pitch without changing the slide setting. Releasing the buttons will return the pitch to the slide setting.

ARM-LIFT HEIGHT ADJUSTMENT:

If the pre-adjusted distance that the CUE LEVER (16) raises the stylus off the record surface is inadequate, it can be adjusted by turning the ARM- LIFT HEIGHT ADJUSTMENT SCREW (26) while simultaneously pushing down on the TONE ARM (6). Clockwise rotation of the screw will decrease the distance and counterclockwise rotation will increase the distance.

Page 5

Image 5
Contents PT-1000 Page Page Precautions FeaturesParts Checklist Assembly and Set-UpOperating Instructions Turntable Section SpecificationsTonearm Section GeneralLeistungsmerkmale EinleitungVorsichtsmaßnahmen Teile-LieferumfangBedienungsanweisungen Regulierung DER Armlifthöhe SpezifikationenPitch BEND-TASTEN Introducción Montaje y configuraciónCaracterísticas PrecaucionesInstrucciones de operación Ajuste DE Altura DEL Alzabrazo EspecificacionesSección DE Tocadisco Sección DE Brazo DE FonocaptorCaractéristiques Montage et configurationPrécautions Liste des piècesMode d’emploi Reglage DE LA Hauteur DE Montee DU Bras Caractéristiques TechniquesPitch Bend Buttons Touches DE Rattrapage Caratteristiche principali IntroduzionePrecauzioni Lista dei componentiIstruzioni per il funzionamento Regolazione DELL’ELEVAZIONE DEL Braccio Specifiche TecnicheGiradischi BraccioDo not attempt to return this equipment to your dealer

PT-1000 II specifications

The Gemini PT-1000 II is a state-of-the-art testing and measurement device that has garnered attention in various industries for its precision and reliability. Designed to meet the rigorous demands of both professionals and enthusiasts, the PT-1000 II boasts a variety of features and technologies that enhance its performance and usability.

One of the main features of the Gemini PT-1000 II is its high-resolution LCD screen, which provides clear and easy-to-read data outputs. This display is coupled with an intuitive user interface, making it simple for users to navigate through its array of functionalities. This user-friendly design ensures that both novices and experts can efficiently operate the device.

The device supports multiple measurement modes, allowing users to perform tests with a high degree of accuracy. This versatility makes it suitable for applications in fields such as electronics, automotive, and HVAC. Furthermore, the PT-1000 II is capable of conducting both analog and digital signal tests, broadening its functionality.

Another remarkable characteristic of the Gemini PT-1000 II is its integration of advanced data logging capabilities. This feature allows users to record measurement results over time, making it an ideal tool for monitoring changes in various parameters. The device can store a significant amount of data, which can later be reviewed or exported for analysis.

In terms of connectivity, the PT-1000 II is equipped with USB and Bluetooth options. This connectivity ensures seamless integration with PCs and other smart devices, enabling users to transfer data quickly and easily. The ability to connect wirelessly adds convenience, especially for fieldwork, where mobility is crucial.

Moreover, the Gemini PT-1000 II utilizes innovative sensor technology, ensuring high accuracy and minimal error margins during measurements. The sensors are designed to operate efficiently across a wide range of temperatures and environments, which enhances reliability in diverse conditions.

With its robust construction, the PT-1000 II is built to withstand the rigors of demanding work environments. The device features a rugged design that is resistant to dust, moisture, and other potential hazards, making it ideal for outdoor use.

In summary, the Gemini PT-1000 II stands out as a leading testing device characterized by its high-quality display, versatile measurement capabilities, advanced data logging, effective connectivity options, innovative sensor technology, and rugged build. Whether for professional, industrial, or personal use, the PT-1000 II is engineered to deliver exceptional performance and reliability in a compact and user-friendly package.