Falcon 4400 manual English, French

Page 59

Appendix E: Laser Safety

International Caution Statements for CLASS 11, 22, 3R3, II4, and IIA5 Laser Devices

English

PSC scanners are certified in the U.S. to conform to the requirements of DHHS/CDRH 21CFR Subchapter J and to the requirements of IEC/EN 60825-1:1998-2001.

Class 1, 2, 3R, Class II, and IIA products are not considered to be hazardous. The scanner contains internally a Vis- ible Laser Diode (VLD) whose emissions do not exceed the maximum limits as set forth in the above regulations. The scanner is designed so that there is no human access to harmful laser light during normal operation, user main- tenance or during prescribed service operations.

CAUTION

If the scan pattern is a single dot when depressing the trigger, discontinue operation and return the scanner to PSC.

CAUTION

Do not attempt to open or otherwise service any components in the optics cavity. Opening or servicing any part of the optics cavity by unauthorized personnel may violate laser safety regulations. The optics system is a factory only repair item.

CAUTION

Use of optical systems with the scanner will increase eye hazard. Optical instruments include binoculars, micro- scopes and magnifying glasses. This does not include eye glasses worn by the user.

French

Ce scanneurs du PSC sont certifié conforme à la norme DHHS/CDRH 21CFR sous-chapitre J et à la norme IEC/ EN 60825-1:1998-2001.

Les produits de class 1, 2, 3R, class II, et de IIA ne sont pas considérés dangereux. Le scanneur contient une diode laser visible (VLD) dont les émissions ne dépassent pas les limites prescrites dans les normes précitées. Le scanneur est conçu de façon à ce qu’il ne soit pas possible d’accéder à la lumière laser pendant l’utilisation normale, l’entretien par l’utilisateur et les fonctions de maintenance prescrites.

ATTENTION

Si, quand la fonction de balayage est lancée, le diagramme de balayage est constitué d’un seul point, cesser d’utiliser le scanneur et le retourner à PSC.

ATTENTION

Ne pas essayer d’ouvrir ou de réparer les composants de la cavité optique. L’ouverture de la cavité optique ou la rép- aration de ses composants par une personne non qualifiée peut entraîner le non-respect des règles de sécurité rela- tives au laser. Le système optique ne peut être réparé qu’en usine.

1.Class 1 applies to IEC/EN STD (Europe).

2.Class 2 applies to IEC/EN STD (Europe).

3.Class 3R applies to the Falcon 44xx using ALR (Advanced Long Range) Laser, only.

4.Class II applies to CDRH STD (US/Canada).

5.Class IIA applies to CDRH STD (US/Canada).

Quick Reference Guide

57

Image 59
Contents Key model Falcon 4400 SeriesPatents PSC IncDisclaimer Table of Contents Appendix E Laser Safety Overview Falcon 4400 SeriesMinimum Desktop Computer Requirements Connecting to a PCGetting Started System RequirementsConnecting your Falcon to a PC Installing ActiveSyncFalcon Key Keypad Handled model Features of the FalconFalcon Scanner and Battery Door Views Feature Function/Description More Features of the FalconBattery Pack Powering the FalconInstalling the Battery Pack Installing the Battery Pack Checking Battery Power Battery Status Indicators Charging the Batteries Battery Power GaugeDock or Charger Falcon Charge LEDTop/Rear View of Single-Slot Dock Charging with the DockBattery Status Display Backup BatteryBattery Discharge Characteristics Setting Up the Mobile ComputerCharging with a Battery Charger Touchscreen Calibration Entering a PasswordEntering Data Radio Card SetupBack View of a Falcon 4420 with a Stylus Using the StylusToday Screen Navigating the DisplaySoft key bar Start Menu Start MenuKeyboard Icon SettingsOn-Screen Keyboard Programs Settings screenKey Name Keypad Function/Description KeypadsOverview Keyboard Indicators Modes are not on Press Fn to enter FN modeIcon FunctionKey Keypad Key KeypadNormal Alpha Mode Key Functions Keypad KeypadLaser Scanning Scanning Bar CodesLaser Beam Positions Laser Bar Code Scanning with 2D ImagerScanning Differences Aiming Beam Positioning Scanning IlluminationOCR Scanning Accessing HelpImage Capture PSC recommends using a straightened paper clip Resetting the FalconWarm Reset Procedure to Warm ResetAfter Warm Reset Hard ResetHard Reset Key Sequence After Hard ResetClean Boot After Clean Boot Hold Power & press Reset ... then press ESC +On the display TroubleshootingProblem Possible Cause Solution Did not chargeIncomplete Problem Possible Cause Solution During dataWas transmitted, or Transmitted data wasTery pack charging has Do the following Start RF Connectivity TroubleshootingTelephone Technical Support Technical SupportPSC Website Support PSC Website TekForum Reseller Technical SupportFalcon 4400 Series with Windows Mobile General Eula Terms and Conditions Transfers, Support Limitation Of Liability Appendix B. Microsoft Windows Mobile Addendum to Eula Software END Appendix C PSC Falcon Windows Mobile Product Series Warranty Radio Frequency Interference Canadian Compliance Statement Laser Safety LabelRegulatory Statements Advisory StatementFrench EnglishItalian GermanSwedish DanishDutch Norwegian FinnishSpanish PortugueseChinese Japanese Page Appendix E Laser Safety Declaration of Conformity Germany United Kingdom Asia Pacific ItalyAustralia Japan France Latin America