Newcon Optik LRB 3000PRO operation manual Compass calibration

Page 20

2 – Target should not have high-reflective surface (white color is not considered high reflective in this case.

3 – Unit shall be well leveled with deviation from 0 not more than ±0.75 degrees. Horizontal direction shall be to Magnetic North (not True North). If devices detects large installation errors (unit is not well leveled or not aimed to the North), then LCD will show result “444”, which means that correction was not performed due to incorrect setup.

Compass calibration

If the System was exposed to a strong magnetic field or was not in use for a long time, the compass accuracy may diminish.

To return the compass into working condition:

ƒSelect CALc from CAL menu

ƒKeeping the unit horizontally, perform one full rotation (360˚) around vertical axis within a minute

ƒIf one rotation does not restore calibration – perform two rotations per a minute.

The normal compass functioning will be restored.

16

Image 20 Contents
LRB 3000PRO Page Important Information Read prior to activationPage Table of Contents Brief Description Principle of operationKey Features Device Appearance Page Display Specifications Optional accessoriesDelivery SET Standard delivery setPower Range FinderSpeed measurement CompassOperation Instructions EnvironmentalMechanics Preparing device for operationMeasurement procedure Factors affecting measuring distance Target selection logicIndividual Measurement and Scanning regimes Operation and service modes Page Accuracy correction Sd, dCompass calibration Data Recall mode Best Measuring Technique Storage and Maintenance Troubleshooting Compass readings are equal to zero at any directionWarranty What This Warranty Does Not CoverCustomer Support Quality Certificate Serial numberNewcon Optik
Related manuals
Manual 28 pages 19.41 Kb