Heath Zenith 9600LED series warranty Wiring, Recommended Grounding Method

Page 2

Wiring

WARNING:Turn power off at circuit breaker or fuse.

Note: All wiring should be run in accordance with the National Electrical Code through conduit or another acceptable means. Contact a qualified electrician if there is any question as to the suitability of the system.

CAUTION: DO NOT connect the RED wire unless you want to control other lights from the motion sensor (see Optional Wiring).

Connect the fixture wires to the wires in the junction box. Twist the wires together and secure with wire connectors.

Recommended Grounding Method

Use a green ground “pigtail” (not provided) and twist one end together with the bare fixture wire and the box ground wire. Secure with a wire con- nector. Secure the other end of the “pigtail” with the GND screw on the X-bar.

Black

Light

Green or Bare

White

Fixture

One Motion Light

White

Light

Light

Fixture

Fixture

Black

Green or

Bare

Two Motion Lights

Black to black

White to white

If you have metal junction box, you may not need the green “pigtail”. If you are unsure about the grounding method, consult your local building code.

2

598-1338-03

Image 2
Contents Requirements FeaturesInstallation UnpackingWiring Recommended Grounding MethodMasterMaster Optional WiringMasterSlave Final Assembly Testing and Adjustments Turn on the circuit breaker and light switchMode Switching Summary Manual override Mode Adjustment of Coverage AreaSpecifications OperationTroubleshooting Guide Symptom Possible Cause SolutionTWO Year Limited Warranty Requisitos CaracterísticasInstalacion DesempaqueMétodo recomendado de conexión a tierra CableadoAdvertencia Desconecte la energía en el cortacircuito Maestra Maestra Conexion AlternaMaestra Esclava Bombillas Montaje del aparato Vatios máximo Cada una Pruebas Y Ajustes Conecte el disyuntor y el interruptor de la luzFase de Sobre control Manual OperaciónResumen de las modalidades Del interruptor Regulación DEL Área DE CoberturaEspecificaciones Guia DE Investigacion DE AveriasGarantía Limitada DE DOS Años Déballage CaractéristiquesExigences Méthode de mise à la terre recommandée CâblageMaîtreMaître Câblage FacultatifMaître Satellite Installation Assemblage FinalEssais ET Réglages Ré-enclenchez le disjoncteur puis ouvrez l’interrupteurRéglage DE LA Zone DE Couverture Mode Contournement ManuelFonctionnement Contournement Auto Fiche TechniqueGuide DE Dépannage Ment ManuelGarantie Limitée DE Deux ANS