14.Raise the Frame (53) to the position shown.

Have a second person hold the Frame until this step is completed.

Orient the Storage Latch (50) so that the large barrel and the Latch Knob (51) are in the posi- tions shown.

Remove the tie from the upper end of the Storage Latch (50). Attach the upper end of the Storage Latch to the bracket on the Frame (53) with a 3/8" x 2" Bolt (3) and a 3/8" Locknut (11). Remove the tie from the lower end of the Storage Latch (50). Keep the holes in the Latch Cap (49) aligned with the holes in the Storage Latch. Make sure to keep the Latch Cap in- side the Storage Latch. Attach the Storage Latch to the bracket on the Base (60) with a 3/8" x 1 3/4" Bolt (8). Note: It may be necessary to move the Frame (53) back and forth to align the Storage Latch with the bracket.

Lower the Frame (53) (see HOW TO LOWER THE TREADMILL FOR USE on page 21).

14

 

11

53

 

3

 

50

 

51

 

Large

 

Barrel

 

60

 

49

8

15.Make sure that all parts are properly tightened before you use the treadmill. If there are sheets of clear plastic on the treadmill decals, remove the plastic. To protect the floor or carpet, place a mat under the tread- mill. Note: Extra hardware may be included. Keep the included hex keys in a secure place; one of the hex keys is used to adjust the walking belt (see pages 23 and 24).

If you purchase the optional chest pulse sensor (see page 20), follow the steps below to install the re- ceiver included with the chest pulse sensor.

16.Make sure that the power cord is unplugged. Remove the indicated #8 x 3/4" Screw (1) and the Access Door (102) from the Console Base (96).

17. Connect the wire on the receiver (A) to the indi-

 

 

cated wire extending from the Console Base

 

 

(96). Hold the receiver so that the antenna is

 

 

oriented as shown and is facing the Console

 

 

Base. Attach the receiver to the plastic posts on

 

 

the Access Door (102) with the two included

96

Wire

small screws.

18. Make sure that no wires are pinched.

102

Small

Reattach the Access Door (102) with the #8 x

1

Screws

3/4" Screw (1). Discard the other wires included

 

A

with the receiver.

 

 

 

Antenna

13

Image 13
Contents Model No. GGTL59608.0 Serial No QUESTIONS?Table of Contents Local electronics store Important PrecautionsPulse sensor is not a medical device Page Before YOU Begin Assembly Do not fully fold the Frame yet Make sure that the power cord is unpluggedOvertighten the Locknut the Wheel must Turn freely Right Upright do not fully tighten the Bolts Yet With a second Bolt Spacer 84, 3/8 x 4 Bolt 3/8 Star WasherBolts yet Attach the other resistance mechanism to 3/4 Bolt 112. Do not fully tighten Resistance KnobRight Upright 79 as described above Attach the other Crosswalk Arm 98 as dePower Again. if the Connectors are not CONCareful not to pinch the wires Be careful not to pinch the wires in the Right Handrail Make sure that no wires are pinched HOW to Plug in the Power Cord Operation and AdjustmentPRE-LUBRICATED Walking Belt Features of the Console Console DiagramHOW to USE the Manual Mode HOW to Turn on the PowerSelect the manual mode Insert the key into the consoleTurn on the fan if desired Select one of the preset workouts. To select one HOW to USE a Preset WorkoutStart the workout HOW to USE the Stereo Sound System Information ModeOptional Chest Pulse Sensor HOW to USE the Crosswalk ArmsHOW to Fold the Treadmill for Storage HOW to Fold and Move the TreadmillHOW to Move the Treadmill HOW to Lower the Treadmill for USEProblem The power turns off during use TroubleshootingCompatible with GFCI-equipped outlets Top Problem The walking belt slows when walked onProblem Solution Exercise Intensity Exercise GuidelinesWorkout Guidelines Exercise FrequencyKey No. Qty Description Part LIST-Model No. GGTL59608.0109 Console Fan Userʼs Manual Exploded Drawing A-Model No. GGTL59608.0 R0509B Exploded Drawing B-Model No. GGTL59608.0 R0509B Exploded Drawing C-Model No. GGTL59608.0 R0509B Exploded Drawing D-Model No. GGTL59608.0 Limited Warranty Ordering Replacement PartsIcon Health & Fitness, Inc., 1500 S W., Logan, UT