Gold's Gym GGTL58608.0, 685 manual Top, Problem The walking belt slows when walked on

Page 22
2–3 in.
Rear Roller Bolts

With the help of a second person, carefully raise the

70

 

 

Uprights (70, 76) as shown. Carefully pivot the Hood

28

76

(28) off.

 

Locate the Reed Switch (39) and the Magnet (6) on

 

 

 

the left side of the Pulley (7). Turn the Pulley until the

1/8 in.

 

7

Magnet is aligned with the Reed Switch. Make sure

 

that the gap between the Magnet and the Reed

 

 

 

Switch is about 1/8 in. (3 mm). If necessary, loosen

39

 

6

the Screw (11), move the Reed Switch slightly, and

 

then retighten the Screw. Reattach the Hood, and run

Top

 

 

the treadmill for a few minutes to check for a correct

 

 

speed reading.

View

 

 

PROBLEM: The incline of the treadmill does not change correctly

SOLUTION: a. With the key in the console, press one of the Incline buttons. While the incline is changing, re- move the key. After a few seconds, re-insert the key. The treadmill will automatically rise to the maximum incline level and then return to the minimum level. This will recalibrate the incline system.

PROBLEM: The walking belt slows when walked on

SOLUTION: a. Use only a single-outlet surge suppressor that meets all the specifications described on page 11.

b. If the walking belt is overtightened, treadmill perfor- b mance may decrease and the walking belt may be-

come damaged. Remove the key and UNPLUG THE POWER CORD. Using the hex key, turn both rear roller bolts counterclockwise, 1/4 of a turn. When the walking belt is properly tightened, you should be able to lift each edge of the walking belt 2 to 3 in. (5 to 8 cm) above the walking platform. Be careful to keep the walking belt centered. Then, plug in the power cord, insert the key, and run the treadmill for a few minutes. Repeat until the walking belt is properly tightened.

c. If the walking belt still slows when walked on, please see the front cover of this manual.

22

Image 22
Contents QUESTIONS? Model No. GGTL58608.0 Serial NoTable of Contents Important Precautions Page Before YOU Begin Make sure that the power cord is unplugged AssemblyFully tighten the Upright Bolts yet Upright do not fully tighten the Upright Bolts Yet Endcap Screws See steps 2 and 4. Fully tighten the twoTighten the Bolts yet Not Connected PROPERLY, the CON Sole MAY be Damaged When Page HOW to Plug in the Power Cord Operation and AdjustmentPRE-LUBRICATED Walking Belt Console Diagram Features of the ConsoleHOW to Turn on the Power HOW to USE the Manual ModeMeasure your heart rate if desired Turn on the fan if desiredSelect one of the personal trainer quick HOW to USE a Personal Trainer QuickProgram ProgramsFollow your progress with the matrix and the displays HOW to Create Your OWN Quick ProgramSelect a custom quick program HOW to USE Your OWN Quick Program Select a custom quick programsInformation Mode HOW to Fold and Move the Treadmill HOW to Move the TreadmillHOW to Lower the Treadmill for USE Troubleshooting Problem The power turns off during useProblem The walking belt slows when walked on TopProblem Solution Workout Guidelines Exercise GuidelinesExercise Intensity Exercise FrequencySuggested Stretches R1108A Key No. Qty. DescriptionKey No. Qty Description Exploded Drawing A-Model No. GGTL58608.0 R1108A Exploded Drawing B-Model No. GGTL58608.0 R1108A Exploded Drawing C-Model No. GGTL58608.0 R1108A Exploded Drawing D-Model No. GGTL58608.0 R1108A Limited Warranty Ordering Replacement PartsIcon Health & Fitness, Inc., 1500 S W., Logan, UT