Pentax R326, R-325(N), R-335(N), R-323(N), R-322(N) instruction manual DataLink DL- 01 Software

Page 49

PSF Software Ver.365

12 DataLink DL- 01 Software

DataLink DL01 Software allows you to send collected data by R-300 to other devices, to receive coordinates data, and to convert the resulting files into a number of common formats.

a) Recommendation for "PN"

It is recommended that "PN" (Point Name) data should consist of less or equal to 4 (one-byte) numeric characters to convert files with DL-01. Because, it may not be converted properly if alphabetic characters or more than 5 (one-byte) numeric characters are used for the "PN".

b) Notes for the data transferring.

Please, be careful about following items for the data transfer with "DL-01".

b-1 Notes for unit.

If you are requested to select unit when you convert data on DL-01, please select unit according to the settings on -300.

b-2 Limitation for each format.

Please, use "CSV" or "DC1( DC-1Z) " format to transfer data to/from -300.

Limitation for the "CSV" format.

With the "CSV" format, "PN" and "PC" (Point Code) data consist of less or equal to 8 (one-byte) characters can be transferred.

Limitations for the "DC1 (DC-1Z)" format.

With "DC1 (DC-1Z)" format, the length of "PN" data should consist of less or equal to 8 (one-byte) characters. And with the "DC1 (DC-1Z)" format "PC" data cannot be transferred.

b-3 Recommended communication settings on R-300.

Recommended settings for “COMMUNICAYTION SETUP” on R-300 special function is as follows.

R-300BPC(DL-01) for “COORDINATES SEND”

1.BAUD RATE:

1200

2.DATA LENGTH:

8

3.PARITY BITS:

NIL

4.STOP BITS:

1

5.SIGNAL CONTROL:

OFF

6.XON/XOFF:

OFF

R-300BPC(DL-01) for “SURVEY DATA SEND”

1.BAUD RATE:

1200-9600

2.DATA LENGTH:

8

3.PARITY BITS:

NIL

4.STOP BITS:

1

5.SIGNAL CONTROL:

OFF

6.XON/XOFF:

OFF

PC(DL-01) R-300 for “COORDINATES RECEIVE”

1.BAUD RATE:

1200

2.DATA LENGTH:

8

3.PARITY BITS:

NIL

4.STOP BITS:

1

5.SIGNAL CONTROL:

OFF

48

Image 49
Contents Document Ver Special Functions PSF Software Ver.365Copyright ESC PowerENT HelpTarget MeasDisp ModeRelations between memories and each Special function Contents DataLink DL- 01 Software ResectionIntroduction IntroductionExample COORD. Stakeout Accessing the Special FunctionsCOORD.STAKEOUT can be Accessing the Special Functions Accessing by Help KEY109 000General pictures of measurement COORD. StakeoutAlphanumeric keys and arrow key JOB Name inputJOB Name selection Number List screen Station Coordinates Station Coordinates inputNumber screen Input the Y and Z Coordinate Coordinates Input screenStation Coordinate which is Backsight Selection screen is viewed Search and call of the stored Station CoordinatesENT key to view the Instrument Height Input screen Coordinates Input Backsight Selection a. Coordinates inputNumber screen Input the Backsight point number Foresight Number List screen after Search and Call of the stored Backsight Point NumberBacksight Point Number Confirm the Backsight Point CoordinatesInput and Stakeout of Foresight Point Number and Coordinates Procedures 2 of 3. StakeoutInput the Foresight point Coordinates Input the Foresight point numberCompare screen Aim at the Backsight point and input Azimuth angle in caseRotate the instrument horizontally and stop Search and Call of the stored Foresight Point Number Distance Stakeout Distance Stakeout ENT Distance StakeoutENT Dist Compare Track / MeasREF.P-P RDMReference Point REF.P.-PObservation of the target point P1 Observation of the reference pointJOB Name ENT Coordinate JOB Name Input CoordinatesJOB Name ENT Coordinates JOB Name Input Search and call of stored Station Coordinates Azimuth input Search and call of the stored Backsight P. NumberENT Description Select Description Input Prism H Measured PointStore / ENT H are offset value Offset ShotsOffset Point ObstacleJOB Name selection Selection keys , ⇒ JOB Name input Selection keysSearch and call of the stored Backsight Coordinates Coordinates input Backsight Coordinates inputCoordinates Input ENT Select Description Input ENT CoordinateTarget point survey Offset point surveyObserving the reference point REMObserving the target ENT Input Prism HJOB Name input Selection keys , ⇒ ResectionStored JOB Name selection Selection keys , ⇒ ENT Station Point InputPoint B survey Point C survey Select ENT Description Select Resection Descriptioninput ENT ENT YPrism H Select Prism H Select ENTJOB Name selection Selection keys ∆ , ∇ Data StorageJOB Name ENT Survey JOB Name Input JOB Name ENT Survey JOB NameENT Description Select Station Setup ENT Station Point InputENT INSTR. H ENT Store SelectSend by input of the stored Coordinates JOB Name Memory ManagerShift to a desired JOB Name Memory ManagerSelect Baud Rate ENT ReceiveDelete by search of the Coordinates JOB Name Delete by input of the Coordinates JOB NameSearch & shift to stored JOB Name Send by input of the Survey JOB NameSurvey Data Send ENT Send by search & call of the Survey JOB Name Delete by search and call of the Survey JOB Name Delete by input and call of the Survey JOB NameENT Over Write Memory Manager ENTDataLink DL- 01 Software Recommended communication settings on DL-01 PN,X,Y,Z,Code First edition TS01101EB2 Mail international@piic.pentax.co.jp