Pentax R-323(N), R-325(N), R-335(N), R-322(N), R326 COORD. Stakeout, General pictures of measurement

Page 12

PSF Software Ver.365

3 COORD. STAKEOUT

General pictures of measurement

With COORD. STAKEOUT measurement, "Stakeout point coordinates" can be staked out in 3 dimensions based on the known "Station point coordinates" and the "Backsight point coordinates or Backsight point azimuth". The horizontal angle, horizontal distance and vertical distance to the stakeout point are automatically calculated as design values, and the differences between the measured values and design values are displayed as deviations. When the coordinate values of the Station point, Backsight point and Stakeout point are recorded on the instrument memory, designation of each measured point number makes it possible to omit the each time coordinates value input.

General pictures

Z

N

Prism height

Backsight point

Staking point

Instrument height

Station point

E

Design values and deviation

N

Z

 

Distance deviation

Horizontal distance

 

design value

 

 

Prism

Horizontal angle

 

design value

Staking point

 

Horizontal angle

Backsight point

deviation

 

Backsight point azimuth

Station point

 

 

E

Prism

Z deviation

Staking point

 

Station point

Z design value

E

11

Image 12
Contents Special Functions PSF Software Ver.365 Document VerCopyright Power ESCENT HelpMeas TargetDisp ModeRelations between memories and each Special function Contents Resection DataLink DL- 01 SoftwareIntroduction IntroductionAccessing the Special Functions Example COORD. StakeoutCOORD.STAKEOUT can be Accessing by Help KEY Accessing the Special Functions000 109COORD. Stakeout General pictures of measurementJOB Name input Alphanumeric keys and arrow keyJOB Name selection Station Coordinates Station Coordinates input Number List screenNumber screen Coordinates Input screen Input the Y and Z CoordinateStation Coordinate which is Search and call of the stored Station Coordinates Backsight Selection screen is viewedENT key to view the Instrument Height Input screen Backsight Selection a. Coordinates input Coordinates InputNumber screen Input the Backsight point number Search and Call of the stored Backsight Point Number Foresight Number List screen afterBacksight Point Number Confirm the Backsight Point CoordinatesProcedures 2 of 3. Stakeout Input and Stakeout of Foresight Point Number and CoordinatesInput the Foresight point number Input the Foresight point CoordinatesCompare screen Aim at the Backsight point and input Azimuth angle in caseRotate the instrument horizontally and stop Search and Call of the stored Foresight Point Number Distance Stakeout Distance Stakeout Distance Stakeout ENTENT Dist Compare Track / MeasRDM REF.P-PReference Point REF.P.-PObservation of the reference point Observation of the target point P1Coordinates JOB Name ENT Coordinate JOB Name InputJOB Name ENT Coordinates JOB Name Input Search and call of stored Station Coordinates Search and call of the stored Backsight P. Number Azimuth inputMeasured Point ENT Description Select Description Input Prism HStore / ENT Offset Shots H are offset valueOffset Point ObstacleJOB Name input Selection keys JOB Name selection Selection keys , ⇒Coordinates input Backsight Coordinates input Search and call of the stored Backsight CoordinatesCoordinates Input ENT Select Description Input ENT CoordinateOffset point survey Target point surveyREM Observing the reference pointObserving the target ENT Input Prism HResection JOB Name input Selection keys , ⇒Stored JOB Name selection Selection keys , ⇒ ENT Station Point InputPoint B survey Point C survey Description Select Resection Descriptioninput ENT ENT Y Select ENTPrism H Select Prism H Select ENTData Storage JOB Name selection Selection keys ∆ , ∇JOB Name ENT Survey JOB Name Input JOB Name ENT Survey JOB NameStation Setup ENT Station Point Input ENT Description SelectENT INSTR. H ENT Store SelectMemory Manager Send by input of the stored Coordinates JOB NameMemory Manager Shift to a desired JOB NameSelect Baud Rate ENT ReceiveDelete by input of the Coordinates JOB Name Delete by search of the Coordinates JOB NameSend by input of the Survey JOB Name Search & shift to stored JOB NameSurvey Data Send ENT Send by search & call of the Survey JOB Name Delete by input and call of the Survey JOB Name Delete by search and call of the Survey JOB NameENT Over Write Memory Manager ENTDataLink DL- 01 Software Recommended communication settings on DL-01 PN,X,Y,Z,Code Mail international@piic.pentax.co.jp First edition TS01101EB2