Pentax R326, R-325(N), R-335(N), R-323(N) Search and Call of the stored Backsight Point Number

Page 19

PSF Software Ver.365

4

 

 

BACKSIGHT COORDONATES INPUT

Input the Backsight Coordinates

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

according to the COORDINATES input.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. POINT No. *

 

 

0025

 

 

 

 

 

 

 

 

 

 

 

 

2.DESCRIPTION

:

-xxxxxx.xxx m

 

 

 

 

3.X COORD.

:

 

 

 

 

 

4.Y COORD.

 

 

xxxxxx.xxx m

 

 

 

 

5.Z COORD.

:

 

xxxxxx.xxx m

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STORE

 

 

 

SELECT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

Press the [ENT] key to view the

 

 

BACKSIGHT AIMING

FORESIGHT NUMBER LIST screen after

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

aiming at the Backsight Point.

 

 

After aiming the Backsight

 

 

 

 

Point, push the

ENT

.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FORESIGHT NUMBER LIST

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. 0000

 

 

 

 

 

 

 

 

 

 

 

 

2. 1234

 

 

 

 

 

 

 

 

 

 

 

3. 0025

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum 4 digits can be inputted on the Backsight number input.

Search and Call of the stored Backsight Point Number

1

 

BACKSIGHT SELECTION

 

 

Press the [ENT] key on 1 COORDINATES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. COORDINATES INPUT

 

INPUT to view the BACKSIGHT NUMBER

 

 

2.FORESIGHT COORD.(AZIMUTH)

 

LIST screen .

 

 

INPUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

BACKSIGHT NUMBER LIST

Move the cursor to your desired

 

 

1. 0000

 

 

 

 

 

Backsight Point Number.

 

 

 

 

 

 

 

 

2. 1234

 

 

 

 

 

 

 

 

3. 0025

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

BACKSIGHT AIMING

Confirm the Backsight Point Coordinates

 

 

After aiming the Back Sight

 

 

 

Point, push the

ENT

 

 

 

and press the [ENT] key.

 

 

 

 

 

 

 

 

After aiming at the Backsight Point, push

 

 

 

 

 

 

 

 

the [ENT] key to view the FORESIGHT NUMBER

 

 

 

 

 

 

 

 

LIST screen.

 

 

 

 

 

 

 

 

18

Image 19
Contents Document Ver Special Functions PSF Software Ver.365Copyright Help PowerESC ENTMode MeasTarget DispRelations between memories and each Special function Contents DataLink DL- 01 Software ResectionIntroduction IntroductionExample COORD. Stakeout Accessing the Special FunctionsCOORD.STAKEOUT can be Accessing the Special Functions Accessing by Help KEY109 000General pictures of measurement COORD. StakeoutAlphanumeric keys and arrow key JOB Name inputJOB Name selection Number List screen Station Coordinates Station Coordinates inputNumber screen Input the Y and Z Coordinate Coordinates Input screenStation Coordinate which is Backsight Selection screen is viewed Search and call of the stored Station CoordinatesENT key to view the Instrument Height Input screen Coordinates Input Backsight Selection a. Coordinates inputNumber screen Input the Backsight point number Confirm the Backsight Point Coordinates Search and Call of the stored Backsight Point NumberForesight Number List screen after Backsight Point NumberInput and Stakeout of Foresight Point Number and Coordinates Procedures 2 of 3. StakeoutAim at the Backsight point and input Azimuth angle in case Input the Foresight point numberInput the Foresight point Coordinates Compare screenRotate the instrument horizontally and stop Search and Call of the stored Foresight Point Number Distance Stakeout Track / Meas Distance StakeoutDistance Stakeout ENT ENT Dist CompareREF.P.-P RDMREF.P-P Reference PointObservation of the target point P1 Observation of the reference pointJOB Name ENT Coordinate JOB Name Input CoordinatesJOB Name ENT Coordinates JOB Name Input Search and call of stored Station Coordinates Azimuth input Search and call of the stored Backsight P. NumberENT Description Select Description Input Prism H Measured PointStore / ENT Obstacle Offset ShotsH are offset value Offset PointJOB Name selection Selection keys , ⇒ JOB Name input Selection keysSelect Description Input ENT Coordinate Coordinates input Backsight Coordinates inputSearch and call of the stored Backsight Coordinates Coordinates Input ENTTarget point survey Offset point surveyENT Input Prism H REMObserving the reference point Observing the targetENT Station Point Input ResectionJOB Name input Selection keys , ⇒ Stored JOB Name selection Selection keys , ⇒Point B survey Point C survey Prism H Select ENT Description Select Resection Descriptioninput ENT ENT YSelect ENT Prism H SelectJOB Name ENT Survey JOB Name Data StorageJOB Name selection Selection keys ∆ , ∇ JOB Name ENT Survey JOB Name InputENT Store Select Station Setup ENT Station Point InputENT Description Select ENT INSTR. HSend by input of the stored Coordinates JOB Name Memory ManagerENT Receive Memory ManagerShift to a desired JOB Name Select Baud RateDelete by search of the Coordinates JOB Name Delete by input of the Coordinates JOB NameSearch & shift to stored JOB Name Send by input of the Survey JOB NameSurvey Data Send ENT Send by search & call of the Survey JOB Name Memory Manager ENT Delete by input and call of the Survey JOB NameDelete by search and call of the Survey JOB Name ENT Over WriteDataLink DL- 01 Software Recommended communication settings on DL-01 PN,X,Y,Z,Code First edition TS01101EB2 Mail international@piic.pentax.co.jp