Healthrider HREL32907.0 manual Now, tighten both M8 x 25mm Patch Screws 22 at the same time

Page 7

4.The Console (5) requires four 1.5V “D” batteries (not included); alkaline batteries are recommended.

IMPORTANT: If the elliptical exerciser has been exposed to cold temperatures, allow it to warm to room temperature before inserting batteries into the Console. If you do not do this, the console dis- plays or other electronic components may become damaged.Remove the battery cover from the Console. Next, insert four batteries into the battery compart- ments. Make sure that the batteries are oriented as shown by the diagrams inside the battery compart- ments. Then, replace the battery cover.

5.Tip: Be careful to avoid pinching the wire harness- es during this step.

While another person holds the Console (5) near the Upright (2), connect the wire harness on the Console to the Upper Wire Harness (86). Insert the excess wire harness into the Upright. Next, attach the Console to the Upright with four M4 x 16mm Screws (66).

6.Identify the Left Handlebar (9), which is marked with an “L” sticker. Insert the Left Handlebar into one of the Handlebar Legs (79); make sure that the Handlebar

Leg is turned so the hexagonal holes are oriented as indicated. Attach the Left Handlebar to the Handlebar Leg with two M8 x 45mm Button Bolts (50) and two M8 Nylon Locknuts (46). Make sure that the Nylon

Locknuts are set inside the hexagonal holes. Do not tighten the Button Bolts yet.

Apply a generous amount of the included grease to the Pivot Axle (97) and to two M8 Large Washers (53). Next, insert the Pivot Axle into the Upright (2) and center it. Apply more grease to both ends of the Pivot Axle.

Slide a Handlebar Spacer (25) onto the short tube on the Left Handlebar (9), and rotate the Handlebar Spacer so the small arrow is pointing toward the floor. Next, slide the Left Handlebar onto the left end of the Pivot Axle (97). Finger tighten an M8 x 25mm Patch Screw (22) with an M8 Large Washer (53) and a Wave Washer (95) into the end of the Pivot Axle. Then, attach a Handlebar Cap (23) by pressing its small tabs into the Handlebar Spacer.

Assemble the Right Handlebar (not shown) and the other Handlebar Leg (not shown) in the same way.

Now, tighten both M8 x 25mm Patch Screws (22) at the same time.

4

Battery

Cover

5

Batteries

5

66

5

86 Wire

Harness

2

6

9

 

Grease

 

 

Tube

 

Grease

97

2

53

22

25

 

23

Arrow

 

 

 

95

46

 

 

 

50

Hexagonal

Holes

79

7

Image 7
Contents Model No. HREL32907.0 Serial No QUESTIONS?Call TOLL-FREE Table of Contents Important Precautions Before YOU Begin Assembly 105 70 83 Now, tighten both M8 x 25mm Patch Screws 22 at the same time Grease103 100 HOW to Adjust the Stride of the Elliptical Exerciser HOW to USE the Elliptical ExerciserFeatures of the Console Select the manual mode HOW to USE the Manual ModeCenter of the dis- play-When the manu Clear plastic on When you are finished exercising, the consoleMeasure your heart rate if desired If there are sheetsHOW to USE a Pulse Control Program See on Select one of the resistance & rpm programs HOW to USE a Resistance & RPM ProgramHandgrip Pulse Sensor Troubleshooting Maintenance and TroubleshootingBattery Replacement HOW to Level the Elliptical ExerciserExercise Frequency Exercise GuidelinesExercise Intensity Workout GuidelinesSuggested Stretches Page Qty Description Part LIST-Model No. HREL32907.0Qty Description Exploded HREL32907.0 Limited Warranty Ordering Replacement PartsIcon Health & FITNESS, INC., 1500 S W., LOGAN, UT