CycleOps 200 PRO, 300 PRO, 400 PRO, 100 PRO manual Replace Hub Batteries 400 Pro/300 Pro only

Page 10

4.Using the new battery (compatible CR2032), remove the battery cover on the back of the cadence sensor by turning counterclockwise approximately one half turn. Replace the old battery with the new battery.

5.Secure the cadence sensor to the main frame using the previously removed bolt and 4mm Allen wrench. Be sure to hold the cadence sensor arm while attaching bolt.

6.Using a 4mm Allen wrench and three chain guard bolts, reattach the chain guard.

NOTE: After replacing the battery, Joule must relearn the coded ID for the sensor. Reference Joule user guide for instructions (avail- able at www.cycleops.com).

Replace Hub Batteries (400 Pro/300 Pro only)

Over time, the batteries that power the electronics in the hub will need to be changed. See Preventative Maintenance for when to replace. The CycleOps Pro Series indoor cycle uses two AA batteries. The battery cap is split to make this task as easy as possible.

1.Rotate the flywheel to access the bolt on the handle side of the battery cap.

2.Using a 2.5mm Allen wrench, re- move the bolt on the battery cap. Pull the plastic battery cap away from the hub using the molded handle.

3.Replace the batteries, paying close at- tention to properly line up the +/- poles, then replace the battery cap and tighten the bolt.

9

Image 10
Contents CycleOps Pro Series Indoor Cycles Table of Contents Handlebar Rear stabilizer Front stabilizer Main frame assemblySeat post longer, reads to Seat post clamp Small L handlesAttach Stabilizer Feet Guard sideLarge L Small L Handles Push Rotate Placement using 6mm Allen wrench Within the clamp. Adjust to desired seatAttach seat to seat post clamp GEnERAl UsE Adjust handlebar Common AdJUsTmEnTs Out of the main frameReplace Hub Batteries 400 Pro/300 Pro only Mm tensioning hardware Adjust Brake Pad 400 Pro only DAILyElectronics WeeklyRadio Frequency RF interference Warranty Manufacturer’s Warranty under normal use