Precor C846 Club Information, Changing the Club Settings, Electrical power must be supplied

Page 15

C O M M E R C I A L P R O D U C T S D I V I S I O N

Club Information

These next few pages provide information that lets you customize the C846 for your Club. It is not information that your customer needs to see. This section covers the following information about how to:

select the units of measure

set maximum workout and pause times

customize a course

display the odometer and other useful information

connect to CSAFE compatible devices

Note: If your customers are interested in the learning more about the C846, you may wish to direct them to the manual available on Precor’s web site (www.precor.com). (The manual, which appears on the web site, does not con- tain the information found in this section.)

CHANGING THE CLUB SETTINGS

The Club “custom” settings are accessed through specific codes that help elimi- nate unauthorized access. Refer to Diagram 9 to locate the keys. Information that you can access and features that can be customized are as follows:

Units of Measure — Select between U.S. Standard and Metric displays.

Maximum Workout Time — Sets a maximum limit on workout time.

Note: Remember the additional five minute cool-down period appended to a completed course, so adjust the maximum time limit accordingly.

Maximum Pause Time — Sets the maximum duration for which a person can “pause” his or her workout.

Limiting the Resistance Range— Set specific resistance range (high, medium, or low) for the cycle.

Changing the Custom Course Resistance Settings — Sets specific resistance settings for a Custom course.

Odometer, Hours of Use, SoftwareVersion, Error Log and Serial Number — The C846 stores the cumulative revolutions, the number of hours that the unit has been in use, the software version and software type (which is valuable when calling customer support), an error log (useful when troubleshooting) and the serial number (another valuable item when calling customer support).

To access the Club settings, the following must occur:

Electrical power must be supplied.

The foot pedal speed must be maintained at 20 revolutions per minute. Or, the optional battery recharger must be plugged into the C846 and connected to an appropriate power source.

Check that the Precor banner appears on the display and maintain the minimum pedal speed.

Press the appropriate key sequences.

page 15

Image 15 Contents
Commercial Self-powered Cycle Persons, take the following precautions Ing any maintenance tasksSafety Approval Hazardous Materials and Proper DisposalEuropean Applications Table of Contents Maintenance Exercising on the C846Courses RFI Radio Frequency Interference C846 SELF-POWERED FeaturesObtaining Service About this ManualEquipment and prevent injuries to yourself Unpacking the C846 Standard EquipmentOther Equipment Setting Up the C846 Installation RequirementsHardware KIT Additional Tools Needed Assembly Instructions Diagram 3 Securing the upright support to the base assembly \zn inch hex key E Diagram 6 Adjusting the seat on C846 Recumbent Testing the Heart Rate Display Supplying Power to the C846Changing the Club Settings Electrical power must be suppliedClub Information RESET, 5, 6, 5, 1, 5, 6 Setting a Workout Time Limit Setting a Pause Time LimitChanging the Units of Measure Limiting the Resistance Range Customizing a Course RESET, 6Revs Hours Using Csafe Standard EquipmentNumeric keypad Enter ResetFeatures on the Display Console C846 DisplaySmartrate Display Informational Displays Prior to Shutdown Upper DisplayLower Display M M E R C I a L P R O D U C T S D I V I S I O N Keypad Tips Keys on the Display ConsoleM M E R C I a L P R O D U C T S D I V I S I O N Course prompt Prompts Default ValueWeight prompt Press Quickstart at Following occurs Precor bannerExercising on the C846 Adjusting the SeatC846 Upright Seat Adjustment C846 Recumbent Seat AdjustmentWorkout Tips Using the Heart Rate Touch CapabilityEnter Quick Steps to Working OUTCooling Down After a Workout PAUSE, Cool Down and Exit FeaturesIs detected A course This is what happensSelecting a NEW Course During a Workout Courses Course FeaturesRate Heart Rate Feature and Target ZonesSmartrate Feature Weight Loss ZoneCardiovascular Zone Cross Country and Hill Climb Courses Manual Mode and the Quickstarttm KEYRandom Course Interval CourseWatts Control Course Weight Loss Course Heart Rate Control CourseResistance Custom Course GOAL-BASED Courses Fitness TestFitness Test Guidelines Fitness Test ends if any one of the following occurs Fitness Test ScoresStoring the Polar Chest Strap MaintenanceCleaning the Equipment InspectionObtain a 3/16-inch and 5/16-inch hex key Servicing the C846 and Long Term Storage Using the Optional Battery RechargerPolar chest strap Heart Rate Troubleshooting TipsDetecting a Heart Beat Touch-sensitive heart rateUpright Exploded Views Upright Exploded Views Upright Exploded Views Upright Exploded Views Upright Exploded Views Recumbent Exploded Views View Recumbent Exploded Views Recumbent Exploded Views Recumbent Exploded Views Thank You and Welcome to Precor How many members do you have? Date of PurchaseProduct Serial Numbers Please indicate the type and number of products purchasedComplete this portion and keep for your records Limited WarrantyWarranty Periods and Coverage Conditions and RestrictionsElectronic Specifications Product Specifications