PROBLEM:

SOLUTION:

The walking belt is off-center or slips when walked on a. If the walking belt is off-center, first remove the

key and UNPLUG THE POWER CORD. If the walking belt has shifted to the left, use the hex key to turn the left idler roller bolt clockwise 1/2 of a turn; if the walking belt has shifted to the right, turn the bolt counterclockwise 1/2 of a turn. Be careful not to overtighten the walking belt. Then, plug in the power cord, insert the key, and run the treadmill for a few minutes. Repeat until the walk- ing belt is centered.

b. If the walking belt slips when walked on, first re- move the key and UNPLUG THE POWER CORD. Using the hex key, turn both idler roller bolts clock- wise, 1/4 of a turn. When the walking belt is cor- rectly tightened, you should be able to lift each side of the walking belt 2 to 3 in. (5 to 7 cm) off the walking platform. Be careful to keep the walking belt centered. Then, plug in the power cord, insert the key, and carefully walk on the treadmill for a few minutes. Repeat until the walking belt is prop- erly tightened.

a

b

23

Image 23
Contents On the WEB QUESTIONS?Model No. PMTL39708.0 Serial No Mon.-Fri a.m.-6 p.m. MT Sat a.m.-4 p.m. MTTable of Contents Important Precautions Treadmill until it is properly assembled. See By an authorized service representative onlyCuit breaker to the off position when Before YOU Begin Assembly Do not fully fold the Frame yet Make sure that the power cord is unpluggedTouch the Upright do not fully tighten Bolts yet Page Tighten the Bolts yet Nected PROPERLY, the Console MAY Be Damaged When the Power isPage PRE-LUBRICATED Walking Belt Operation and AdjustmentHOW to Plug in the Power Cord Features of the Console Console DiagramInsert the key into the console HOW to Turn on the PowerHOW to USE the Manual Mode Select the manual modeMeasure your heart rate if desired HOW to USE a Preset Workout HOW to USE the Dumbbells Information ModeHOW to Move the Treadmill HOW to Fold and Move the TreadmillHOW to Lower the Treadmill for USE Compatible with GFCI-equipped outlets TroubleshootingProblem The power does not turn on Problem The power turns off during useTop Problem The walking belt slows when walked onProblem Solution Exercise Frequency Exercise GuidelinesExercise Intensity Workout GuidelinesSuggested Stretches Key No. Qty Description Part LIST-Model No. PMTL39708.0107 Filter Wire Userʼs Manual Exploded Drawing A-Model No. PMTL39708.0 R0509A Exploded Drawing B-Model No. PMTL39708.0 R0509A Exploded Drawing C-Model No. PMTL39708.0 Exploded Drawing D-Model No. PMTL39708.0 R0509A Icon Health & Fitness, Inc., 1500 S W., Logan, UT Ordering Replacement PartsLimited Warranty