ProForm PFTL81405.0 user manual Problem The walking belt slows when walked on

Page 28

PROBLEM: The walking belt slows when walked on

SOLUTION: a. Use only a single-outlet surge suppressor that meets all of the specifications described on page 9.

b. If the walking belt is overtightened, treadmill perfor- mance may decrease and the walking belt may be per- manently damaged. Remove the key and UNPLUG THE POWER CORD. Using the included allen wrench, turn both rear roller adjustment bolts counterclockwise 1/4 of a turn. When the walking belt is properly tight- ened, you should be able to lift each edge of the walk- ing belt 3 to 4 inches off the walking platform. Be careful to keep the walking belt centered. Plug in the power cord, insert the key, and run the treadmill for a few min- utes. Repeat until the walking belt is properly tightened.

b

3–4”

Rear Roller Adjustment Bolts

c. If the walking belt still slows when walked on, see the front cover of this manual.

PROBLEM: The walking belt is off-center or slips when walked on

SOLUTION: a. If the walking belt is off-center, first remove the key and UNPLUG THE POWER CORD. If the walking belt has shifted to the left, use the allen wrench to turn the left rear roller adjustment bolt clockwise 1/2 of a turn; if the walking belt has shifted to the right, turn the bolt counterclockwise 1/2 of a turn. Be careful not to over- tighten the walking belt. Plug in the power cord, insert the key, and run the treadmill for a few minutes. Repeat until the walking belt is centered.

b.If the walking belt slips when walked on, first remove the key and UNPLUG THE POWER CORD. Using the allen wrench, turn both rear roller adjustment bolts clockwise 1/4 of a turn. When the walking belt is cor- rectly tightened, you should be able to lift each edge of the walking belt 3 to 4 inches off the walking platform. Be careful to keep the walking belt centered. Plug in the power cord, insert the key, and walk on the treadmill for a few minutes. Repeat until the walking belt is properly tightened.

a

b

28

Image 28
Contents Model No. PFTL81405.0 Serial No QUESTIONS?Call TOLL-FREE Table of Contents Important Precautions Page Back Before YOU BeginRight Side Assembly Bolts and then firmly tighten them Not overtighten the Nut the Wheel should turn freelyTape Treadmill Operation HOW to Plug in the Power CordPRE-LUBRICATED Walking Belt Features of the Console HOW to Turn on the Power HOW to USE the Manual ModeMeasure your heart rate if desired Turn on the fan if desiredHOW to USE a Preset Program Select one of the preset programsFollow your progress with the displays HOW to Create a Custom Program Select one of the custom programsHOW to USE a Custom Program HOW to USE a Heart Rate Program Follow your progress with the displays HOW to Connect Your Portable Stereo HOW to Connect Your Home Stereo HOW to Connect Your ComputerAudio Adapter Cable HOW to Connect Your VCRPressVCR. the Play button on your CD player or Measure your heart rate if desired Follow the on-line instructions to start Program HOW to USE Programs Directly from OUR WEB SiteReturn to the treadmill and stand on the foot Information MODE/DEMO Mode Optional Chest Pulse SensorHOW to Fold the Treadmill for Storage HOW to Fold and Move the TreadmillHOW to Move the Treadmill HOW to Lower the Treadmill for USE Troubleshooting Problem The power turns off during useSwitch. Make sure that the gap between the Magnet Reed Switch is about 1/8. If necessary, use a TopProblem The walking belt slows when walked on Exercise Guidelines Exercise IntensityWorkout Guidelines Exercise FrequencySuggested Stretches R705A Key No. Qty. DescriptionExploded DRAWING-Model No. PFTL81405.0 101 104 7883 105 106 107 103 102 Limited Warranty HOW to Order Replacement PartsIcon Health & FITNESS, INC., 1500 S W., LOGAN, UT