ProForm DTL62950 user manual Top, Problem The walking belt slows when walked on

Page 23

With the help of a second person, carefully raise the Upright Base (97) as shown. Carefully pivot the Hood (113) off.

Locate the Reed Switch (22) and the Magnet (19) on the left side of the Pulley (18). Turn the Pulley until the Magnet is aligned with the Reed Switch. Make sure that the gap between the Magnet and the Reed Switch is about 1/8”. If necessary, loosen the Screw

(23)and move the Reed Switch slightly. Retighten the Screw. Reattach the Hood, and run the treadmill for a few minutes to check for a correct speed reading.

 

 

97

 

113

 

1/8”

 

18

 

 

23

 

 

 

22

19

 

 

Top

 

 

View

 

 

PROBLEM: The walking belt slows when walked on

SOLUTION: a. Use only a single-outlet surge suppressor that meets all of the specifications described on page 8.

b. If the walking belt is overtightened, treadmill perfor- mance may decrease and the walking belt may be- come damaged. Remove the key and UNPLUG THE POWER CORD. Using the allen wrench, turn both rear roller adjustment bolts counterclockwise, 1/4 of a turn. When the walking belt is properly tightened, you should be able to lift each side of the walking belt 2 to 3 inches off the walking platform. Be careful to keep the walking belt centered. Plug in the power cord, in- sert the key, and run the treadmill for a few minutes. Repeat until the walking belt is properly tightened.

b

2”–3”

Rear Roller Adjustment Bolts

c. If the walking belt still slows when walked on, please call our Customer Service Department, toll- free.

PROBLEM: The walking belt is off-center or slips when walked on

SOLUTION: a. If the walking belt is off-center, first remove the key and UNPLUG THE POWER CORD. If the walking belt has shifted to the left, use the allen wrench to turn the left rear roller bolt clockwise 1/2 of a turn; if the walking belt has shifted to the right, turn the bolt counterclockwise 1/2 of a turn. Be careful not to overtighten the walking belt. Plug in the power cord, insert the key, and run the treadmill for a few minutes. Repeat until the walking belt is centered.

b. If the walking belt slips when walked on, first re- move the key and UNPLUG THE POWER CORD. Using the allen wrench, turn both rear roller bolts clockwise, 1/4 of a turn. When the walking belt is cor- rectly tightened, you should be able to lift each side of the walking belt 2 to 3 inches off the walking platform. Be careful to keep the walking belt centered. Plug in the power cord, insert the key, and carefully walk on the treadmill for a few minutes. Repeat until the walk- ing belt is properly tightened.

a

b

23

Image 23
Contents Customer HOT Line QUESTIONS?Model No. DTL62950 Serial No Important Precautions Table of ContentsPage Back Before YOU BeginRight Side Make sure that the power cord is unplugged AssemblyUpright Base 107 Wire 116 Cylinder 108 PRE-LUBRICATED Walking Belt Operation and AdjustmentHOW to Plug in the Power Cord Features of the Console Console DiagramHOW to USE the Manual Mode HOW to Turn on the PowerTurn on the fan if desired Measure your heart rate if desiredOn the foot Rails Avoid movSelect one of the preset programs HOW to USE a Preset ProgramSelect a heart rate program HOW to USE a Heart Rate ProgramEnter your age Enter a maximum speed settingAudio Cable HOW to Connect Your MP3 Player or CD PlayerHOW to Connect Your Portable Stereo HOW to Connect Your Computer HOW to Connect Your Home StereoPress the Play button on your MP3 player, CD Player, or VCR HOW to Connect Your VCRMeasure your heart rate if desired Return to the treadmill and stand on the foot Directly from OUR WEB SiteFollow the on-line instructions to start Program Optional Chest Pulse Sensor Information MODE/DEMO ModeHOW to Level the Treadmill HOW to Lower the Treadmill for USE HOW to Fold and Move the TreadmillHOW to Fold the Treadmill for Storage HOW to Move the TreadmillProblem The power turns off during use TroubleshootingTop Problem The walking belt slows when walked onExercise Frequency Conditioning GuidelinesExercise Intensity Workout GuidelinesSuggested Stretches Qty Description R1104AQty Exploded DRAWING-Model No. DTL62950 108 109 111 101 103 100 112 107 104 Icon Health & FITNESS, INC., 1500 S W., LOGAN, UT HOW to Order Replacement PartsLimited Warranty