3. Connect neutral ground wire and neutral wire
B |
C |
E |
Connect neutral ground wire (E) and place hooked end (hook facing right) of neutral wire (white or center wire) (C) of direct wire cable under center screw of terminal block (B). Squeeze hooked ends together and tighten screw.
4. Connect ground wire
A F
Connect ground wire (green or bare) (F) of direct wire cable to external ground conductor screw (A). Tighten screw.
5. Connect remaining wires
Place hooked ends of remaining direct wire cable wires under outer terminal block screws (hooks facing right). Squeeze hooked ends together and tighten screws. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with
3-Wire Direct Wire Connection
IMPORTANT: Use where local codes permit connecting
1. Prepare your 3-wire cable for direct connection
1" | |
(25 | mm) |
|
3½" | |
(89 | mm) |
|
Direct wire cable must have 5 ft. (1.52 m) of extra length so dryer may be moved if needed.
Strip 31/2" (89 mm) of outer covering from end of cable. Strip insulation back 1" (25 mm). If using
2. Remove center screw
B
Remove center terminal block screw (B).