Rowenta DG 560, DG 580 manual Rinsing OUT the Boiler, Water Recommendations

Page 7

RINSING OUT THE BOILER

Do not use descaling agents.

To ensure optimum steam performance, the boiler must be rinsed out after every 10 uses. If your tap water is hard increase the frequency.

1.Check that the generator is unplugged and cold.

2. Fill the boiler 3/4 full with tap water.

3. Shake the boiler for a few moments and then empty it over a sink.

4. Repeat the process

5. Wipe the generator base regularly with a damp cloth and wipe dry.

6.Never hold the generator under the tap.

Boiler Cap

To ensure a proper seal, please check the red rubber ring in the safety cap for wear and tear regularly. If wear is noted, replace ring. Replacement rings are available through our main service centers.

WATER RECOMMENDATIONS

Tap water

Rowenta irons are designed to be used with REGULAR TAP WATER (up to 12 grains of hardness). If your water is harder than this, Rowenta recommends mixing half tap water with half distilled water which reduces the hardness; or just use inexpensive bottled spring water. Never use 100 % distilled water as this can cause the iron to spit and leak.

Softened water

There are many types of household water softeners and the water from many of them is perfectly acceptable for use in steam generator. However, some types of softeners, particularly those that use chemicals such as salt, can cause the appliance to leak or spit during use. If you experience this type of problem, we recommend that you try using inexpensive bottled spring water or untreated tap water. Never use 100 % pure distilled water.

Once you have changed water it will take several uses to correct the problem. Rowenta recommends trying the steam function for the first time on an old towel or cloth that can be discarded to avoid damaging your clothes.

Iron and other impurities

If your water supply contains large amounts of iron or organic matter, these minerals can collect inside the appliance and eventually appear as brown stains. If you experience these problems Rowenta recommends using inexpensive bottles spring water.

Never use 100 % pure distilled water.

Image 7
Contents Master Instructions for Use Important Safety Instructions Filling Boiler While In Use Before USEHelpful Hints Filling the BoilerRegulator Steam IroningDRY Ironing DG580Vertical Steam Filling the Boiler While in USE Cleaning and MaintenanceNever use household cleaners, descalers or solvents Cleaning the SoleplateWater Recommendations Rinsing OUT the BoilerIssues Possible causes Solutions TroubleshootingAlways remember Page Medford, MA Rowenta Inc