®

DIGITAL CONTROL INCORPORATED

Troubleshooting

 

Problem/Concern

Causes/Solutions

Section to Consult

 

1999 in bottom window of

Transmitter is asleep (wake it up by

“Electrical Interference/

 

receiver, indicating no signal

rotating the drill string).

Background Noise Check”

 

is being received from the

Dead batteries in the transmitter.

in Signal Interference

 

transmitter.

Section

 

Broken transmitter.

 

 

Transmitter Section

 

 

Overheated transmitter.

 

 

 

 

 

 

Transmitter is out of range of receiver.

 

 

 

A number ranging from 200 to

Receiver is receiving background noise.

“Electrical Interference/

 

700 in bottom window of

 

Background Noise Check”

 

receiver and transmitter is not

 

in Signal Interference

 

active.

 

Section

 

Depth suddenly decreases

Ultrasonics have not been zeroed and

“Ultrasonic Function” in

 

18–24 inches (46–61 cm).

receiver is being set on the ground for

Receiver Section

 

 

depth reading. Due to the likelihood of

 

 

 

 

interference, do not measure with the

 

 

 

 

receiver on the ground.

 

 

 

Depth after calibration

Depth measurement mode in receiver has

“Changing the Depth

 

displays as 297–305 instead

been inadvertently changed from inches

Measurement Units” in

 

of 119–121.

(English) to centimeters (metric).

Receiver Section

 

Incorrect depth.

Interference.

“Electrical Interference/

 

 

Ultrasonics improperly set.

Background Noise Check”

 

 

in Signal Interference

 

 

Bad calibration.

 

 

Section

 

 

Weak signal from the transmitter.

 

 

“Ultrasonic Function” in

 

 

Receiver is not directly over transmitter

Receiver Section

 

 

when taking a depth reading (trigger must

 

 

 

 

be released).

 

 

 

 

Receiver malfunction.

 

 

 

 

 

 

 

 

Erratic information on

Interference.

“Electrical Interference/

 

receiver.

Low battery in receiver.

Background Noise Check”

 

 

in Signal Interference

 

 

Moisture inside the equipment. Call DCI

 

 

Section

 

 

for information about field methods for

 

 

Remote Display Section

 

 

“drying” out the equipment. Moisture can

 

 

be caused by condensation which occurs

 

 

 

 

when the equipment is repetitively moved

 

 

 

 

to and from a warm environment and a

 

 

 

 

cold one.

 

 

 

Remote display has dashes

Receiver is set on channel 0 (the telemetry

“Changing the Receiver’s

 

across windows.

is off).

Channel Setting” in

 

 

Receiver is set to a different channel than

Receiver Section

 

 

 

 

 

 

remote display.

 

 

 

 

 

 

 

DigiTrak® Mark III Operator’s Manual

63

 

Page 71
Image 71
Digitrex 3-3000-00a-F manual Troubleshooting, Problem/Concern Causes/Solutions Section to Consult