5.During the tone, click the trigger again and continue to hold the receiver level and steady. You will then hear 2 beeps followed by a long
6.During the
7.Continue to hold the receiver in this position until you hear 3 beeps indicating that the second calibration point was found and the calibration procedure is complete.
8.Reset the ultrasonic measurement to zero and check the depth reading while the receiver is sitting on the ground directly above the transmitter. To verify a good calibration, check the depth at two different elevations above ground using the ultrasonics, as described below under “Confirming Proper Calibration.”
NOTE: If you hear 2 long beeps, there has been a calibration error, which can be caused by an unstable or weak signal or a failed ultrasonic reading.
To calibrate (older receivers manufactured prior to 1995 that haven’t been updated):
1.Place the transmitter into the drill head housing and place on the ground.
2.Cover the transmitter with a flat surface (e.g., a clipboard, piece of cardboard, plywood, etc.) to pro- vide an ultrasonic response surface.
3.With the trigger held in, position the receiver over the tool using the plus/minus
NOTE: Mark I Receivers without upgrades do not show
4. Follow the instructions given above for calibrating newer receivers beginning with step 4.
Confirming Proper Calibration
The ultrasonic function can be used to confirm proper calibration when the transmitter is below ground. Check the depth measurement with the receiver held at one position (above the transmitter), then raise the receiver to a new elevation, click the trigger to set the ultrasonics, and note the depth reading. If the depth readings are the same (within 2 inches [5 cm]), then the calibration is good. If the depth readings are not within 2 inches, then the depth/distance readings cannot be relied on and recalibration should be performed.