Cable Transmitter | ® |
|
Viewing the Cable System Battery Status
The percentage of required voltage will be displayed in the top left window of the remote display for 2 seconds when the transmitter’s temperature increases by 4°C, which will be displayed in the top right window. To manually access the voltage status, turn the remote display off and on and observe the top left window after the firmware version is displayed. The voltage status is displayed in percent remaining (above the minimal necessary voltage) and is based on a 28V DC power source. Therefore, 28V will display as 100%, 19V as 50%, 12V as 25%, 9V as 0%.
When a standard DCI battery pack is installed into the remote display, rather than the Cable Transmitter Power Supply, it will automatically switch from the cable transmitter mode. Pitch, roll, temperature, and battery status will again be received by telemetry from the DigiTrak Receiver.
Operation
The cable transmitter is located using the FNLP, RNLP, and PLL in the same manner as other DigiTrak Transmitters, except the receiver will not display the transmitter’s pitch, roll, and battery or temperature
With the cable transmitter inside the housing/tool and grounded to the drill, complete a
Note that, because the cable transmitter emits twice the signal strength of a
Ensure that the remote display and power supply are connected directly to the power source, not through the drill’s DC power supply.
A multimeter should be available for power testing/troubleshooting. For detailed instructions on trouble- shooting the Cable Transmitter System, please contact Customer Service at
62 | DigiTrak® Mark III Operator’s Manual |