Cable Transmitter | ® |
|
Cable Transmitter
The cable transmitter has the same general features and capabilities as the other DigiTrak Transmitters but with increased depth range. The dimensions of the cable transmitter are the same as those of the 2- cell DigiTrak Transmitters (DT, DX, and DXP). However, there is also a power/signal cable extending from the rear metal grounding cap. The metal grounding cap must make solid contact with the interior of the housing, which is grounded through the drill. The function of the wire is to provide power to the transmitter and to send the pitch, roll, voltage, and temperature information to the remote display.
The cable transmitter is inserted into the transmitter housing, using the cable extraction/insertion tool, so that the cable extends through the back of the housing. A compression fitting is used to seal the transmitter compartment from drilling fluid/water. Optimal compression fitting characteristics include a washer in the uphole side of the rubber stopper (inside compression fitting) and/or a
The Cable Transmitter System has the following characteristics:
¾The calibration procedure is a
¾An input voltage between 12V and 28V DC.
¾The typical power source is one or two 12V DC
|
|
|
| Drill Rods | Housing | ||
|
|
|
|
| |||
White |
|
|
|
|
|
| |
|
| Black |
|
|
|
| |
|
|
|
|
|
| ||
|
| Cable |
| Cable Transmitter | |||
|
|
|
|
| |||
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
+ |
| – |
|
|
|
| |
|
| 12 Volt | Ground |
|
|
| |
|
|
|
|
|
|
|
Green
Compression
Drill Rig
Power Supply
Remote Display
Fitting
Cable
End Plug
Housing to Transmitter
Base is Negative
Contact for Grounding
Connecting Cable Transmitter to Power Supply and Remote Display
60 | DigiTrak® Mark III Operator’s Manual |