Console Channel Configuration List dialog box

Send

Choose the Send button to send the console channel configuration data to the respective interface module. This procedure must be performed before the interface module will operate with the new configuration. Only configured and configured-and-active (C and C/A prefixes) configurations may be sent. All configuration data is sent to the MOM Controller Board; the Audio configuration is sent directly out from there to the respective interface module Controller Board. A "Send to Console Successful" message will be received to confirm that the data was received by the interface module Controller Board. Bus Slot configuration data is compared to the current configuration at the CEC/IMC Manager; if different, it is sent to the MOM Controller Board (if not, no further action is taken by the system) and when the MOM Controller Board receives this new data it will send an acknowledgment message back to the CEC/IMC Manager, which will then display the confirmation box: "Do you want to activate TDM Bus Slots? OK - will cause all CTRL boards to reset." Choose OK to activate TDM Bus Slots (resetting Controller Boards) with the new Bus Slot configuration data, choose Cancel to not activate TDM Bus Slots with the new Bus Slot configuration data (keeping the previous configuration) and return to the Console Channel Configuration List dialog box.

 

 

 

 

 

 

 

 

Close

 

 

 

 

 

 

 

 

 

 

Close

 

 

 

 

Choose

the

button

to

exit

the

Console Channel Configuration List dialog

box and

return to

the

CEC/IMC Manager main window. Any "**" prefixed consoles appearing in the Configured/Active Consoles list box will be removed and returned to the Configurable Consoles list box.

3.11.2 Console User Profile Configuration

This option is used to configure each console in the system and its associated user profiles. Ten different profile set-ups may be configured for each console, each having a unique personality. These setups are done from the Console User Profile Configuration dialog box, Figure 27. From the CEC/IMC Manager menu bar select Configure System / Console Configuration / User Profile to display the Console User Profile Configuration dialog box.

3-112

Page 142
Image 142
Ericsson LBI-39224 manual Console User Profile Configuration, Console Channel Configuration List dialog box Send, 112