1.VERIFY that the MIGRATE.BAT utility has been executed to save the original (DOS) CEC/IMC Manager configuration.

2.Insert the "Install" CEC/IMC Manager V5.0 for Windows NT diskette and execute SETUP.EXE. This setup utility will:

Copy all necessary Executables and DLLs

Install the CEC/IMC Manager server as a service

Install the CEC/IMC Manager GUI

Setup Program Groups and CEC/IMC Manager Icons

Execute the necessary registry edits

3.(OPTIONAL) Insert the "Install" SNMP Agent Diskette and execute SETUP.EXE.

4.Insert the "Migrate Utility" diskette and execute MIGRATE.BAT to transfer the previous (DOS) CEC/IMC Manager configuration to the just installed (Windows NT)

CEC/IMC Manager. This should be the second time MIGRATE.BAT was run since the original (DOS) CEC/IMC Manager configuration was saved using this utility on the (DOS) CEC/IMC Manager machine. In a DOS Window:

From the C:\WINMOM prompt type a:\migrate TO.

5.Reboot the CEC/IMC Manager PC.

6.Double-click on the CEC/IMC Manager icon (in the WINMOM program group) to execute the CEC/IMC Manager GUI.

IMPORTANT NOTE

Expect to see "NOVRAM MISMATCH" Popup windows. These occur because the DOS MOMPC did not save Bus/Slots to disk. Although the Migration utility preserved much of the configuration, the bus/slots at the CEC/IMC Manager will be zero and the MOM Controller will hold the valid Bus/Slots configuration. By following steps 7-13 the entire slot database should be stored to the CEC/IMC Manager V5.0 hard disk.

2-4

Page 26
Image 26
Ericsson LBI-39224 manual Important Note