Image 217

LBI-39224

data is not successfully broadcast to all required devices a "MOM Communication Error" or "Device not active" notify box will be displayed. The assigned Controller Board (device type and assignment in the I/O definition) must be installed and active for the event definition to operate. Normally, only modified event definitions are sent to the MOM.

Send

Choose the Send button to send the currently selected I/O event data to the MOM Controller Board. The key and message event information will be sent to but not stored in MOM Controller NOVRAM.

Send All

Choose the Send All button to send/resend all I/O event configurations. This is useful to refresh all I/O configurations if a Controller Board or console has been replaced or upgraded and has lost its I/O event data.

Save All

Choose the Save All button to save all I/O event configurations to the CEC/IMC Manager hard disk.

 

 

 

 

 

 

 

 

Close

 

 

 

 

 

 

 

 

 

 

Close

 

 

 

 

Choose

the

button

to

exit

the

Auxiliary I/O Event Configuration

dialog

box and

return to

the

CEC/IMC Manager main window. If any changes have been made and not saved, you will be prompted (Write Changes to Disk?) to save and exit (Yes), exit without saving (No), or cancel the Close command and remain in the dialog box (Cancel).

3.19 ACTIVATE TDM BUS SLOTS

No interface modules will receive the new bus and slot settings stored in the MOM until each one is reset. These are the settings from the various interface module configurations performed earlier in the setup procedure which were sent to the MOM when Send was performed from those dialog boxes. This can be done by cycling power or by individually resetting each interface module's Controller Board. This should be done after both the bus and slot configurations have been sent to the MOM.

If the CEC/IMC is equipped with firmware V4.03 or later, this can be done automatically from the CEC/IMC Manager by selecting the