Ericsson LBI-39224 manual Appendix B Logged Warning Definitions, Logged Message Data

Models: LBI-39224

1 330
Download 330 pages 24.07 Kb
Page 289
Image 289

LBI-39224

7.2APPENDIX B - LOGGED WARNING DEFINITIONS

LOGGED

LOGGED

WARNING

WARNING

MESSAGE

DATA

 

 

W00-xxx:

(none)

UNKNOWN

 

WARNING

 

W01-048:

The callee type value

UNDEFINED -

that

generated

the

CALLEE TYPE

warning.

 

W01-049:

The caller type value

UNDEFINED -

that

generated

the

CALLER TYPE

warning.

 

W02-028:

Console number

that

OUT OF RANGE -

generated

the

CONSOLE NUMBER

warning.

 

W02-032:

Low

byte contains

OUT OF RANGE -

bus number.

High

BUS_SLOT

byte

contains

slot

 

number.

 

W02-033:

Audio

channel

OUT OF RANGE -

number that generated

AUDIO CHANNEL

the warning.

 

CAUSE/

CORRECTIVE

ACTION

A warning has been generated within the CEC/IMC, but the

CEC/IMC Manager cannot

determine what it is. This is usually a result of a Controller Board residing in the system with firmware prior to version 2.00 or with a firmware version more

recent than the CEC/IMC

Manager's software version. Corrective Action: Ensure all Controller Boards in system are equipped with firmware version

2.00or greater and the CEC/IMC Manager contains a software version greater than or equal to the most recent Controller Board firmware being used.

Unknown callee type was found.

Unknown caller type was found.

Console number found that was not in the allowed range of 1 – 32.

Bus or slot number found that was greater than the maximum number allowed.

Audio channel number found that was not in the allowed range.

B-1

Page 289
Image 289
Ericsson LBI-39224 manual Appendix B Logged Warning Definitions, Logged Message Data