LOGGED

LOGGED

 

ERROR

ERROR

 

MESSAGE

DATA

 

 

 

 

E11-143:

None

 

ENCRYPTION FAIL -

 

 

LICENSE DATA BAD

 

 

 

 

 

 

 

 

LBI-39224

CAUSE/

CORRECTIVE

ACTION

This invalid feature data system error is issued if no license data is available. Starting with Group 12, CEC/IMC Software will require licenses to specify the operational features and maximum capacities for a CEC/IMC Node. The licenses must be installed at the CEC/IMC Manager PC for the desired feature/capacity to take effect and cannot be changed by the end user. If this error occurs all licenses should be checked using the license administration tool - see EDACS Product Licenses for Windows NT Administration Guide (AE/LZT 123 1906 R1A).