Ericsson LBI-39224 manual Timeout Safety

Models: LBI-39224

1 330
Download 330 pages 24.07 Kb
Page 296
Image 296

LBI-39224

LOGGED

LOGGED

WARNING

WARNING

MESSAGE

DATA

 

 

 

W10-114:

Channel number that

TIMEOUT - SAFETY

was cleared.

 

TIMER

 

 

 

 

W11-118:

The GSC address of

REDUNDANT -

the secondary

node

PRIMARY/

that switched.

 

SECONDARY

 

 

SWITCH

 

 

W12-036:

The Audio

Board

LINK FAIL - HDLC

number that failed to

CHANNEL B

respond.

 

W13-099:

Callee ID

that

could

CALLEE NOT FOUND

not be found.

 

- CIM MODULE

 

 

 

TABLE

 

 

 

W13-100:

Callee ID

that

could

CALLEE NOT FOUND

not be found.

 

- CIM CHANNEL

 

 

 

DATABASE

 

 

 

W14-101:

Channel number.

NDC DATA - SUM

 

 

 

DATA

 

 

 

W15-129:

Number

of

SAIDs

UNAVAILABLE -

allocated

to

this

SAID VALUE

switch.

 

 

CAUSE/

CORRECTIVE

ACTION

The NIM (StarGate systems) has received no activity on an active channel for approximately ten (10) minutes. The NIM will clear the channel at this point and issue this warning.

Secondary MIM Controller Board has switched to become a primary MIM Controller Board.

An Audio Board with slots allocated to it has failed to respond to S-Frame polls from the Controller Board. This warning could indicate the high speed serial link (HDLC Protocol) between the Controller Board and one of its Audio Boards is not functioning. This warning will also be generated if slots are allocated but the board is not installed in the switch.

The given callee ID could not be found in the CIM Module Table.

The given callee ID could not be found in the CIM Channel Database.

An attempt was made to sum data on the same audio channel.

All SAIDs (System Assigned Group IDs) allocated to this switch are currently in use by other patches/simulselects.

B-8

Page 296
Image 296