LBI-39224

LOGGED

LOGGED

 

WARNING

WARNING

 

MESSAGE

DATA

 

 

 

 

CAUSE/

CORRECTIVE

ACTION

Notes for W18-xxx warnings: Controller Boards with firmware versions prior to 2.12 do not log these warnings. For Controller Boards with firmware versions 2.12 or greater but less than 3.00, W18-132 will be logged for changes in device type, version number, and date/time stamp. For these versions also note the following: 1) the node ID of the source node will always be FFh, 2) the upper byte of the data word will contain the new device type value and the lower byte will be either the previous device type value, if the device type has changed, or the value FFh. For CCI Controller Board version 2.12 and greater, the source node ID will always be FFh.

W18-131:

Previous

assignment

NOVRAM CLEAR -

value in upper

byte,

NEW DEVICE

current

assignment

ASSIGNMENT

value in lower byte.

 

 

W18-132:

Previous type value in

NOVRAM CLEAR -

upper

byte,

current

NEW DEVICE TYPE

type

value

in

lower

 

byte.

 

 

 

 

W18-133:

Either the

computed

NOVRAM CLEAR -

checksum,

 

or

the

INVALID CHECKSUM

value 0055h

 

 

W19-115:

The SAID

value

DENIED - PATCH/

assigned to

the

SIMULSELECT

patch/simulselect.

Non-volatile RAM (NOVRAM) cleared on Controller Board due to a change in device assignment DIP switches. This only occurs on certain device personalities.

Non-volatile RAM (NOVRAM) cleared on Controller Board due to a change in device type DIP switches.

Non-volatile RAM (NOVRAM) cleared on Controller Board due to one of the following: 1) computed checksum did not match the stored checksum, 2) a key value stored in NOVRAM did not match the value in the 80C186 ROMs (e.g. version number, date/time stamp, etc.).

A site has denied the activation of a patch or simulselect. If multiple sites deny it, only the first denial received is logged.

Note for W20-xxx warnings: These warnings are applicable only for StarGate systems that have conventional channels installed on more than one CEC/IMC in the StarGate network.