LBI-39224

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOGGED

LOGGED

 

 

 

 

CAUSE/

 

ERROR

 

ERROR

 

 

CORRECTIVE

 

MESSAGE

 

DATA

 

 

 

 

ACTION

 

 

 

 

 

 

 

E08-18:

No information in the

 

A Controller

Board

device

DEVICE CONFLICT -

data word.

 

 

 

type/assignment

setting

is

CONTROL BOARD

 

 

 

 

 

conflicting

with

another

board's

 

 

 

 

 

 

setting. For example a VMIM 5

 

 

 

 

 

 

and a MIM 5 will conflict with

 

 

 

 

 

 

each other. The main information

 

 

 

 

 

 

is the device type/assignment in the

 

 

 

 

 

 

error heading. With the correct

 

 

 

 

 

 

hardware revision, the ID LED will

 

 

 

 

 

 

also be flashing on the offending

 

 

 

 

 

 

board. Also, sometimes this error

 

 

 

 

 

 

only applies to one board.

 

 

 

 

 

 

(Example CCI, or second MOM

 

 

 

 

 

 

mistakenly

installed in

main

 

 

 

 

 

 

CEC/IMC

rack).

Corrective

 

 

 

 

 

 

Action: The offending board must

 

 

 

 

 

 

be removed and its type/assignment

 

 

 

 

 

 

setting must be changed to not

 

 

 

 

 

 

conflict with another device. The

 

 

 

 

 

 

other device should also be

 

 

 

 

 

 

displaying this error and it should

 

 

 

 

 

 

also be reset.

 

 

E09-139:

Data

field

is

the

 

The T1/E1 Interface Card has lost

T1/E1 INTERFACE -

T1/E1 Interface Card

 

its T1/E1 signal.

 

 

LOSS OF SIGNAL

affected (1-8).

 

 

 

 

 

 

 

 

E09-140:

Data

field

is

the

 

A valid T1/E1 receive framing

T1/E1 INTERFACE -

T1/E1 Interface Card

 

sequence no longer exists at the

LOSS OF FRAME

affected (1-8).

 

 

 

T1/E1

Interface

Card.

Two

SYNC

 

 

 

 

 

possible causes would be that the

 

 

 

 

 

 

frame format changed at one end of

 

 

 

 

 

 

the T1/E1 link or loss of the T1/E1

 

 

 

 

 

 

signal.

 

 

 

 

E09-141:

Data

field

is

the

 

A Frame Slip occurs when a

T1/E1 INTERFACE -

T1/E1 Interface Card

 

clocking

frequency mismatch (at

EXCESSIVE FRAME

affected (1-8).

 

 

 

the card level) causes received

SLIPS

 

 

 

 

 

frames to be repeated or discarded.

 

 

 

 

 

 

Excessive frame slips indicate a

 

 

 

 

 

 

clock failure on the T1/E1 Interface

 

 

 

 

 

 

Card.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 