LBI-39224

Figure 35 Conventional Channel Configuration

Dialog Box

A CEC/IMC Manager can only program/configure its (local) conventional channels. When local conventional channel programming is saved at a CEC/IMC Manager, the channel aliases and channel LIDs of the changed channels are sent to all other CEC/IMCs in the StarGate network. This allows remote conventional channel information to be viewed (read-only function) at all other CEC/IMC Managers in the

StarGate network. When viewing remote conventional channel information, displayed read-only information includes the remote channel's CEC/IMC switch assignment number (33 – 64), its LID number, its alias, and the range of conventional channels assigned to the remote CEC/IMC. The switch assignment number and the channel range can be viewed in the Channel Location group of the Conventional Channel Configuration dialog box, Figure 35. The table below, Table 7, breaks out channel locations for 64 channels maximum per CEC/IMC.

In CEC/IMC software/firmware previous to version 4.0, LIDs 1 thru 64 had to be reserved for conventional channels if these channels were going to be patched to trunked groups. In version 4.0 (and later), any free LID can be assigned to a conventional channel. This prevents requiring LIDs 1 thru 255 for conventional channels in a StarGate network.

3-149

Page 179
Image 179
Ericsson LBI-39224 manual Conventional Channel Configuration Dialog Box, 149