Send Mod

Choose the Send Mod button to send the selected module configurations (more than one module may be selected) to the CEC/IMC MOM. This action will program the selected module.

NOTE

This function can be very important during software upgrades. Part of the upgrade procedure is to clear NOVRAM on all boards in the CEC/IMC. This function allows you to reprogram the LRIM after the NOVRAM has been cleared with the configuration data stored on the CEC/IMC Manager hard disk (See Read Disk).

Program LRIM

Choose the Program LRIM button to send all configured module data for the selected LRIM to the CEC/IMC MOM. This command is analogous to a send all (modules) command.

Close

Choose the Close button to exit the Logging Recorder Configuration dialog box and return to CEC/IMC Manager main window. Choosing this command does not save or send any changes made to LRIM configuration.

3.16EDACS DATA GATEWAY (EDG) CONFIGURATION

Each EDACS Data Gateway (EDG) channel should be allocated a TDM time slot. This is accomplished using a CIM designated for EDG use. In addition, EDG configurations should be setup in accordance with one or more of the following manuals: EDG Technical Description (LBI-38961), EDG Installation and Maintenance (LBI 38962), EDG User's Reference Manual (LBI-38963), and EDG Configuration Reference Manual (LBI-38964).