LBI-39224

Emergency Clear Silences Alarm

Select this check box to enable the EMERGENCY tone to be silenced when the EMERGENCY is cleared by anyone. Unselect to disable, the tone will remain until cleared by dispatcher.

Minimum Alarm Volume

This is the minimum level at which an emergency tone will be heard. The greater of the module volume or this volume will be used for the emergency tone level. Select this value (0 - 32) from the drop-down list box.

Auto Programmed Alarm Volume

This is the volume setting for incoming non-monitored emergency calls. Select this value (0 - 32) from the drop-down list box.

Table 4 Console Individual Call Levels

INDIVIDUAL

CALL PRIVILEGE

CEC/IMC

MANAGER

CONFIGURATION

CONSOLE EFFECT

disabled (no Individual

all units must be

Call privileges)

removed from the

 

console's privilege list

 

(See Section 3.11.4)

 

 

partial

desired units are

 

enabled in the console's

 

privilege list and the

 

"Monitor ICALL

 

Privilege" is disabled

 

(check box unselected)

 

 

full (Supervisor

desired units are

console set-ups only)

enabled in the console's

 

privilege list and the

 

"Monitor ICALL

 

Privilege" is enabled

 

(check box selected)

 

 

a dispatcher cannot make or monitor any Individual Call

a dispatcher can make

Individual Calls to

units on the privilege list but cannot monitor any Individual Call

a dispatcher can make Individual Calls to any unit and can monitor any Individual Call

Save and Send Console User Profile Configurations

When the console user profile configuration is complete, save (write) the new configuration to the CEC/IMC Manager hard disk. Failure to perform this function may result in loss of the configuration database for this console. The user profile configurations must be sent to the respective console before they will take effect. These actions are

3-119

Page 149
Image 149
Ericsson LBI-39224 manual Save and Send Console User Profile Configurations