Ericsson LBI-39224 manual Cic

Models: LBI-39224

1 330
Download 330 pages 24.07 Kb
Page 295
Image 295

LBI-39224

LOGGED

LOGGED

WARNING

WARNING

MESSAGE

 

DATA

 

 

 

 

 

"CIC

 

Denied"

 

warning and the caller

 

and

callee

of the

 

failed confirmed call.

 

"CTIM

Duplex"

 

warning and the caller

 

and

callee

of the

 

failed confirmed call.

"DVIM Encrypt" warning and the caller and callee of the failed confirmed call.

"MIM Sec Ack" warning and the caller and callee of the failed confirmed call.

"Site Queued" warning and the caller and callee of the failed confirmed call.

"Site Sys Busy" warning and the caller and callee of the failed confirmed call.

 

"Site

 

Denied"

 

warning and the caller

 

and callee

of the

 

failed confirmed call.

W10-018:

No data, the Node ID

TIMEOUT -

device

assignment

CONTROLLER

and device type fields

BOARD

of

the

warning

 

identify the board.

CAUSE/

CORRECTIVE

ACTION

The encrypted Jessica/CTIS call was denied at the landline interface.

A "call back" was not received from the landline interface for the encrypted Jessica/CTIS call. This "call back" is required for the full duplex operation as well as ringing tone connections.

The DVIM did not encrypt the landline-to-radio call.

A Secondary Acknowledgment was not received from the MIM for the landline originated encrypted Jessica/CTIS call.

The landline originated encrypted Jessica/CTIS call was queued at the site.

The landline originated encrypted Jessica/CTIS call received a "System Busy" from the site.

The landline originated encrypted Jessica/CTIS call was denied at the site.

A Controller Board in the CEC/IMC did not respond to a poll from the MOM Controller Board. The board will be marked as inactive at the CEC/IMC Manager. This warning will occur when a Controller Board is removed from

the CEC/IMC. Other times indicate a problem with the reported Controller Board.

B-7

Page 295
Image 295
Ericsson LBI-39224 manual Cic