LBI-39224

 

TO

 

 

TO

NETCLOCK/2

 

CEC/IMC

REMOTE OUTPUT

 

MANAGER

PORT

COMM PORT

 

5

TDATA

RXD

2

 

 

 

 

TXD

 

 

 

 

(N.C.)

3

 

 

 

 

 

 

 

9

GND

GND

5

 

 

 

 

 

 

 

 

 

 

 

 

 

(DB-9 MALE)

 

(DB-9 FEMALE)

9-Pin CEC/IMC Manager COM Port

TO

NETCLOCK/2

REMOTE OUTPUT

PORT

5TDATA

9GND

TO

CEC/IMC

MANAGER

COMM PORT

TXD

(N.C.)

 

2

 

RXD 3

GND 7

(DB-9 MALE)

(DB-25 FEMALE)

25-Pin CEC/IMC Manager COM Port

Figure 60 NETCLOCK/2 Remote Output Connections

6.2.2 Software Installation Notes

The NETCLOCK/2 interface is integrated into the Microsoft Windows NT operating system. The Timeserv.exe must be configured by editing the Timeserv.ini as discussed in Timeserve.wri.

6.2.3 Additional Considerations

The following topics in the NETCLOCK/2 Instruction Manual are very important and should be reviewed closely prior to connecting the NETCLOCK/2 to the CEC/IMC Manager.

Time Data Format

Propagation Path Delay

Path Delay Switches

6-5

Page 279
Image 279
Ericsson LBI-39224 manual Software Installation Notes, Additional Considerations