LBI-39224
Caller
The Unit ID of the console currently utilizing this patch/simulselect.
Site Mask
The sites currently involved in this patch/simulselect. This is a 32 bit value in hex format, where each bit corresponds to one of the 32 possible sites, i.e. bit 1⇒site 1, bit 2⇒site 2, etc. The rightmost bit is bit 1. If the bit is set, the corresponding site has responded with an "Active" for this patch/simulselect. For example, the value 080E0211
wouldbeinbinaryformat: 0000 1000 0000 1110 0000 0010 0001 0001. Now it is easy to see that the bits 1, 5, 10, 18, 19, 20, 28 are set, indicating that sites 1, 5, 10, 18, 19, 20, and 28 are active in this patch/simulselect.
Deactivate
Choose the Deactivate button to deactivate a selected patch/simulselect. The Deactivate command is sent just to those sites with the active patch/simulselect. The sites then notify the consoles that the patch/simulselect has been deactivated. This is the preferred method of deactivating a patch/simulselect.
Delete
Choose the Delete button to delete a selected patch/simulselect. Delete sends a deactivate command to the sites with the active patch/simulselect, and also sends the deactivate (delete) command to the consoles. Patches/simulselects normally should not be deleted or deactivated using the Delete button, this should be used only if the patch/simulselect does not respond to the Deactivate command.
Close
Choose the Close button to exit the Patch and Simulselect View dialog box and return to the CEC/IMC Manager main window.
3.12DIGITAL VOICE CHANNEL CONFIGURATION
In order to support digital voice console dispatch, the CEC/IMC must be equipped with at least one Digital Voice Interface Module (DVIM). Each DVIM supports up to