LBI-39224

(async) ports, up to 5, are assigned first and then synchronous (sync) ports are assigned.

Save And Send PIM T1/E1 Configurations

Any

T1/E1 Digital Site Configuration

dialog

box

or

T1/E1 Interface Card Auto-configuration

dialog box

changes

must

be sent before the changes will come into effect at the CEC/IMC. This reprograms the PIM Controller Boards and T1/E1 Interface Cards. The new configurations must be saved before sent to the CEC/IMC, if sending is attempted before saving a "Site data must be saved to disk prior to send" message box will appear. Save and send may be performed either from the T1/E1 Interface Card Auto-configurationdialog box only, or from the Site Channel Configuration List dialog box, similar to Audio Board save and send.

T1/E1 Interface Card Auto-configuration dialog box

Save

Choose the Save button to perform an immediate save of the currently selected site-type interface module's channel configuration. The channel configuration is saved on the CEC/IMC Manager's hard disk drive. Any previous channel configuration for the "site," if present, is erased and replaced with the current channel configuration. If the CEC/IMC Manager is running remotely or as a part of the EDACS Network Manager, this configuration is saved on the CEC/IMC Manager server, typically local to the CEC/IMC; it is not saved at the remote location.

Send

Choose the Send button to send the T1/E1 site channel configuration data to the respective interface module. This procedure must be performed before the interface module will operate with the new configuration. Only configured and configured-and-active (C and C/A prefixes) configurations may be sent. All configuration data is sent to the MOM Controller Board; the T1/E1 configuration is sent directly out from there to the respective interface module Controller Board. A "Send to Site Successful" message will be received to confirm that the data was received by the interface module Controller Board. Bus Slot configuration data is based on the channel assignment in the Set Site Channel Disbursement field (one bus slot per channel assigned) and is compared to the current configuration at the CEC/IMC Manager; if different, it is sent to the MOM Controller Board (if not, no further

3-80