Ericsson LBI-39224 manual Overflow MOM

Models: LBI-39224

1 330
Download 330 pages 24.07 Kb
Page 293
Image 293

 

 

 

 

 

 

 

 

 

 

 

LBI-39224

 

 

 

 

 

 

 

 

 

 

LOGGED

 

LOGGED

 

 

 

 

CAUSE/

 

 

WARNING

WARNING

 

CORRECTIVE

 

MESSAGE

 

DATA

 

 

 

 

ACTION

 

 

 

 

 

 

 

 

 

W07-120:

(none)

 

 

 

 

A new error message has been

OVERFLOW - MOM

 

 

 

 

 

 

received, but the MOM error status

ERROR ARRAY

 

 

 

 

 

 

array is full. The status of the new

 

 

 

 

 

 

 

error will not be stored.

 

 

W08-084:

Message group value

 

Unsupported

message

group

CALL BLOCK -

that

generated

the

 

between consoles.

 

 

 

INTERCONSOLE

warning.

 

 

 

 

 

 

 

 

 

 

 

W08-112:

DVIM

 

 

 

 

The DVIM did not have digital

CALL BLOCK - NO

device/assignment

 

 

decryption channel available for a

CIRCUIT

 

 

 

 

 

 

radio-originated encrypted call.

 

 

 

 

 

 

 

Wide area (multisite) radio-to-radio

 

 

 

 

 

 

 

calls are routed.

 

 

 

 

W09-113:

The

message

group,

 

Multiple

units

 

attempted

to

CALL ROUTING -

subgroup, caller

and

 

transmit to the same callee at the

CONTENTION

callee of the call that

 

same time.

The

CEC/IMC

will

 

was

routed

only

to

 

only allow one active transmitter

 

dispatch consoles due

 

on a talk group. The "rejected" call

 

to contention with an

 

will be routed to all dispatch

 

already active call.

 

consoles but will not be routed to

 

 

 

 

 

 

 

other sites. This leaves the sites all

 

 

 

 

 

 

 

hearing

the

same

(original)

 

 

 

 

 

 

 

transmitter,

but

the

consoles

 

 

 

 

 

 

 

hearing all transmissions.

 

 

W09-125:

(see below)

 

 

 

 

Confirmed

Call

related

warnings.

CALL ROUTING -

 

 

 

 

 

 

This warning is generated from

CONFIRM FAIL

 

 

 

 

 

 

multiple causes:

 

 

 

 

 

The caller and

callee

 

Radio PTT causes: A confirmed

 

of

the

 

failed

 

group call did not receive working

 

confirmed

call.

The

 

channel

assignments

from

all

 

failure reason, as well

 

required sites for the confirmed

 

as a bit mask of all

 

group.

The call will time out and

 

required sites that did

 

transmit in any event after 6-10

 

not

successfully

 

seconds.

 

 

 

 

 

 

respond

is

also

 

 

 

 

 

 

 

 

 

included.

Each

bit

 

 

 

 

 

 

 

 

 

corresponds

to

a

site

 

 

 

 

 

 

 

 

 

number

 

(1-32):

 

 

 

 

 

 

 

 

 

00000001H = Site 1,

 

 

 

 

 

 

 

 

 

80000000H = Site 32

 

 

 

 

 

 

 

 

 

 

"Time Out"

 

 

No

response

 

received

from

 

 

 

 

 

 

 

expected site(s).

 

 

 

B-5

Page 293
Image 293
Ericsson LBI-39224 manual Overflow MOM