match the switch assignment number set by the DIP switches on the

MOM Controller Board. See CEC/IMC Digital Audio Switch Installation, Set-Up And Troubleshooting (LBI-38938) for MOM Controller Board DIP switch configuration details.

Table 5 maps the conventional channel allocation numbers in a StarGate network when the maximum number of conventional channels per CEC/IMC is set to sixty-four (64). Table 6 shows the mapping for thirty-two (32) maximum channels per CEC/IMC. As shown in these tables, the conventional channel allocations recycle with higher switch assignment numbers. Therefore, when assigning switch assignment numbers, ensure the conventional channel allocations are unique at each CEC/IMC. For example, conventional channels should not be installed at CEC/IMC 33 and CEC/IMC 37 if the maximum number of conventional channels per CEC/IMC is equal to sixty-four (64). Similarly, conventional channels should not be installed at CEC/IMC 33 and CEC/IMC 41 if the maximum number of conventional channels per CEC/IMC is equal to thirty-two (32).

Table 5 Switch Assignment Number-to-Conventional Channel

Allocation Mapping for StarGate Networks (Max. Conv. Channels

per CEC/IMC = 64)

CEC/IMC SWITCH

CONVENTIONAL CHANNEL

ASSIGNMENT NUMBERS

ALLOCATIONS

 

 

 

 

 

 

33, 37, 41, 45, 49, 53, 57, 61

1

– 64

 

 

 

34, 38, 42, 46, 50, 54, 58, 62

65

– 128

 

 

35, 39, 43, 47, 51, 55, 59, 63

129 – 192

 

 

36, 40, 44, 48, 52, 56, 60, 64

193 – 255

 

 

 

 

 

 

Table 6 Switch Assignment Number-to-Conventional Channel

Allocation Mapping for StarGate Networks (Max. Conv. Channels

per CEC/IMC = 32)

CEC/IMC SWITCH

CONVENTIONAL CHANNEL

ASSIGNMENT NUMBERS

ALLOCATIONS

 

 

 

 

33, 41, 49, 57

1 – 32

 

 

34, 42, 50, 58

33 – 64

 

 

35, 43, 51, 59

65 – 96

 

 

 

 