LBI-39224

Device Type

This field displays the interface module type: MIM, NIM, etc. (currently only MIMs, NIMs, and PIMs can be equipped with T1/E1 Interface Cards).

Device Assign

This field displays the setting of the interface module Controller Board dip switches (site assignment number).

Status

Card Number

This field indicates which (active) cards within the interface module the subsequent data fields reference. Each interface module will eventually be able to support up to eight (currently only one) T1/E1 Interface Cards, with only four cards active at any given time (See Cards Active below.).

Sig Active

This field indicates if a T1/E1 signal is being received. If the T1/E1 Interface Card detects a T1/E1 signal being received this field will be "Y," and "N" if not. At the T1/E1 Interface Card LED DS5 (labeled "SIG") will also be illuminated if this field is "Y."

Frame Sync

This field indicates if frame synchronization exists. If the T1/E1 Interface Card detects a valid T1/E1 receive framing sequence this field will be "Y," and "N" if not. At the T1/E1 Interface Card LED DS6 (labeled "SYNC") will also be illuminated if this field is "Y."

Clock

This field indicates which system clock (A/B) is providing the clocking function for the card.

Line Relay

This field will be used to indicate redundancy status in later code releases.

Cfg Data

This field indicates if configuration data exists for the card (Y/N). If the T1/E1 Interface Card has received a database this field will be set to "Y," and "N" if not.

4-27