Ericsson LBI-39224 manual Dc E&M Ptt, Dc Dc/E&M Ptt

Models: LBI-39224

1 330
Download 330 pages 24.07 Kb
Page 193
Image 193

LBI-39224

Tone (E&M PTT)

Standard tone signaling on all but PTT (station transmit) commands, E&M M-lead signaling on PTT commands. Standard tone signaling can be modified per State Table (low- level) configuration on a per command basis.

Tone (Tone/E&M PTT)

Standard tone signaling on all commands, PTT commands also include E&M M-lead signaling. Standard tone signaling can be modified per State Table (low-level) configuration on a per command basis.

DC

Standard DC (direct current) signaling on all commands, no E&M M-lead signaling. Standard DC signaling can be modified per State Table (low-level) configurations on a per command basis.

DC (E&M PTT)

Standard DC signaling on all but PTT commands, E&M M-lead signaling on PTT commands. Standard DC signaling can be modified per State Table (low-level) configurations on a per command basis.

DC (DC/E&M PTT)

Standard DC signaling on all commands, PTT commands also include E&M M-lead signaling. Standard DC signaling can be modified per State Table (low-level) configurations on a per command basis.

Causeway

The EDACS Causeway feature allows direct or "hard" patching/simulselecting of a conventional channel to a trunked talk

group. Each conventional channel can be Causeway patched/simulselected to a trunked group using the trunked group's Group ID (GID) number. See Section 3.14.2, Causeway Patch / Simulselect, for more information on Causeway Patch/Simulselect

operation.The Causeway group in the Conventional Channel Configuration dialog box is the configuration point for Causeway. Causeway default = "None."

3-163