LBI-39224

7.APPENDIXES

7.1APPENDIX A - LOGGED ERROR DEFINITIONS

LOGGED

LOGGED

ERROR

ERROR

MESSAGE

DATA

 

 

E00-xxx:

 

UNKNOWN ERROR

 

E01-019:

Data field is the

HW FAIL - AUDIO

Board affected.

BOARD

 

CAUSE/

CORRECTIVE

ACTION

An error has been generated within the CEC/IMC, but the CEC/IMC Manager cannot determine what it is. This is usually a result of a Controller Board residing in the system with firmware prior to version 2.00 or with a firmware version more recent than the

CEC/IMC Manager software

version. Corrective Action: Ensure all Controller Boards in system are equipped with firmware version 2.00 or greater and the CEC/IMC Manager contains a software version greater than or equal to the most recent Controller Board firmware being used.

Audio board type does not match configuration data, i.e. analog board, but configured for digital.

A-1

Page 281
Image 281
Ericsson LBI-39224 manual Appendix a Logged Error Definitions, Logged Error Message Data, Cause Corrective Action