4.Connect the NETCLOCK/2 to an unused CEC/IMC Manager COM port. See the cable wiring diagrams that follow.

The NETCLOCK/2 has two RS-232 serial ports. One is an output that transmits the 26-character ASCII time/date data once each second in Format 0 or Format 1. This is called the 1/sec interface or the "REMOTE OUTPUT."

The other port responds to commands from the CEC/IMC Manager by transmitting a 26-character ASCII time/date data in Format 0, Format 1, or Format 2. This port transmits the data on the next even second after receiving an ASCII "T" from the CEC/IMC Manager. This is the T- CMD or "SERIAL COM" port. Refer to the section of the NETCLOCK/2 instruction manual concerning NETCLOCK/2 data formats for additional details.

6.2.1 Hardware Installation Notes

TIME DATA FORMAT Select the required data format:

FORMAT 0 No date setting.

FORMAT 1 Date setting available.

FORMAT 2 Only available when using the T-CMD interface. Must use the Time Zone Correction setting at the CEC/IMC Manager. No date setting capability.

T-CMD Interconnections

The T-CMD interface (RS-232) requires a 9-pin male connector at the NETCLOCK/2. The CEC/IMC Manager end may be either 9-pin female or 25-pin female, depending on the specific configuration of the PC. (See Figure 59 below.)