two VMIM/CIA sets thus providing up to a total of sixty-four conventional channel interfaces per CEC/IMC. A VMIM is formed by a Controller Board and up to eight Audio Boards.

VMIM-related channel configurations are performed from the Site Channel Configuration dialog box. Although not required, it is recommended that VMIM channel configurations be accomplished prior to CIA rack-related conventional channel configurations which are described later in CONVENTIONAL CHANNEL CONFIGURATION on page 3-145.

VMIM "Site" Selection

Prior to actual channel configuration, the interface module to be configured must be selected. From the CEC/IMC Manager menu bar select Configure System / CEC/IMC Configuration / VMIM. When

VMIM is selected

two

new

choices are

made

available:

Audio Configuration

(VMIM audio

channel configuration)

and

Conv. Interface Adapter Configuration

(conventional

channel

configuration).

Select

Audio

Configuration

to display

the

Site Channel Configuration List dialog box for VMIM configuration.

Figure 22 VMIM Configuration Menu

Each Site Channel Configuration List dialog box displays the configurable "sites" and configured/active "sites." An active "site" represents an active Controller Board control data link. In the case of a

3-83