Ericsson LBI-39224 manual T1/E1 Interface Card-Equipped MIM Configuration

Models: LBI-39224

1 330
Download 330 pages 24.07 Kb
Page 65
Image 65

LBI-39224

MOM Controller Board receives this new data it will send an acknowledgment message back to the CEC/IMC Manager, which will then display the confirmation box: "Do you want to activate TDM Bus Slots? OK - will cause all CTRL boards to reset." Choose OK to activate TDM Bus Slots (resetting Controller Boards) with the new Bus Slot configuration data, choose Cancel to not activate TDM Bus Slots with the new Bus Slot configuration data (keeping the previous configuration) and return to the Site Channel Configuration List dialog box.

Close

Choose the Close button to exit the Site Channel Configuration List dialog box and return to the CEC/IMC Manager main window. Any "**" (unconfigured and unsaved) sites appearing in the Configured/Active Sites list box will be removed and returned to the Configurable Sites list box.

T1/E1 Interface Card-Equipped MIM Configuration

This section describes configuration for channels of T1/E1 Interface Card-equipped interface modules (currently only MIMs, NIMs, and PIMs are so equipped). Channel configurations are performed from the T1/E1 Digital Site Configuration dialog box (Figure 18) and from the T1/E1 Interface Card Auto-configurationdialog box (Figure 19). As was the case with Audio Board-equipped site-type interface modules,

only those "sites" which were selected in the Site Channel Configuration List dialog box are available for channel configuration.

NOTE

Like the CEC/IMC Audio Board, each T1/E1 Interface Card within a CEC/IMC interface module must have a unique board address setting. This address is 1 - 8 (addresses 2 - 8 are currently not available).

3-35

Page 65
Image 65