System Options dialog box (Configure System / System Options / Multisite Settings). This does not reset unit timers or change unit timer reset values, so if "Multisite Unit Logout" is selected (enabled) the unit timers will again decrement from the previously set values.

Command Logout

Command logout instantly logs the requested unit off of all sites. The command logout option can be selected to mark and logoff operator selected units when it is not desired to have units automatically log off the CEC/IMC (timed logout).

Multisite Unit Logout has two modes of operation, Timed Logout and Command Logout. These two modes are NOT exclusive; if a situation develops where a unit must be command logged off, this can be done regardless of the Logout Timer status. A brief description of each follows.

NOTE

In order for a call to NOT be routed to a particular group/site, ALL units must be logged off so that Group Count is equal to zero.

Timed Logout

A unit's multisite timer is set to a predetermined time each time it (the radio) keys. Timed logout logs units off of all sites after the requested unit has not shown any activity (keyed or login to another site) for the predetermined time. Multisite timers for all units are set-up via the Unit/Group Locations and Unit Logout (Multisite Unit Logout in System Options menu) dialog box and they are maintained by (stored in) the MOM Controller Board.

A unit timer is maintained for each unit, and has the following characteristics:

Set at the CEC/IMC Manager and stored in MOM Controller Board NOVRAM.

Set from 0 to 24 hours in 15 minute increments.

Set ALL timers to the same value.

SEND timers by.

3-191