33

COMMAND

[LVOLL,aaa,bbb,ccc,ddd,eee,fff, ggg,hhh,iii,jjj,kkk,lll,mmm,nnn,o oo,ppp]

[LVOLL,?]

[LVOLR,aaa,bbb,ccc,ddd,eee,fff, ggg,hhh,iii,jjj,kkk,lll,mmm,nnn,o oo,ppp]

[LVOLR,?]

DESCRIPTION

Preload left channel output volume level for all outputs. Must send a [TAKE] command to execute changes.

Where

oaaa = -550 to 90 for output 1 o bbb = -550 to 90 for output 2 o ccc = -550 to 90 for output 3 o ddd = -550 to 90 for output 4 o eee = -550 to 90 for output 5 o fff = -550 to 90 for output 6 o ggg = -550 to 90 for output 7 o hhh = -550 to 90 for output 8 o etc.

Note: Level is set in .5 dB steps . For example, – 23.5dB is entered as -235

Queries any previously loaded LVOLL commands.

Preload right channel output volume level for all outputs. Must send a [TAKE] command to execute changes.

Where

oaaa = -550 to 90 for output 1 o bbb = -550 to 90 for output 2 o ccc = -550 to 90 for output 3 o ddd = -550 to 90 for output 4 o eee = -550 to 90 for output 5 o fff = -550 to 90 for output 6 o ggg = -550 to 90 for output 7 o hhh = -550 to 90 for output 8 o etc.

Note: 90 equals max (+9.0 db), 000 equals factory default (0 db), -550 equals minimum (-55db)

Queries any previously loaded LVOLR commands.

Auxiliary Commands

The MSX1616 contains two auxiliary communications ports, port 2 and port 3 (see Setup Commands to properly configure ports). You can use both ports to control other devices or equipment that accept RS232/RS-422/RS-485 command strings. The switcher can store command strings to an input, an output and/or presets (see Preset Commands). It can force these commands out or send them when it executes an input, output, or preset.

COMMAND

[PCPpx]

DESCRIPTION

Enable/disable projector port.

Where

op = 2 for port 2, 3 for port 3

ox = 0 to disable, 1 to enable, ? to query