COMMAND

[PCHpIiiabcde] [PCHpIii?]

[PCHpOooabcde] [PCHpOoo?]

[PCHpPmmmabcde] [PCHpPmmm?]

[PCLpIiiabcde] [PCLpIii?]

[PCLpOooabcde] [PCLpOoo?]

DESCRIPTION

Loads hex command string to an input up to 60 characters.

Where

op = 2 for port 2, 3 for port 3 o ii = 01 – 16 for input

o abcdef… = hex string to be stored o abcdef = ?, queries current label

Loads hex command string to an output up to 60 characters.

Where

op = 2 for port 2, 3 for port 3 o oo = 01 – 16 for output

o abcdef… = hex string to be stored o abcdef - ?, queries current label

Loads hex command string to a preset up to 60 characters.

Where

op = 2 for port 2, 3 for port 3 o mmm = 001 - 256 for preset

o abcdef… = hex string to be stored o abcdef - ?, queries current label

Loads ASCII command string to an input up to 60 characters.

Where

op = 2 for port 2, 3 for port 3 o ii = 01 – 16 for input

o abcdef… = hex string to be stored o abcdef - ?, queries current label

Note: When controlling Inline products that also use brackets as delimiters, replace open bracket [ with ‘ and closed bracket ] with " in the abcde… portion of the command. When this command is sent out the command port the ‘will automatically be replaced with []. "

Loads ASCII command string to an output up to 60 characters.

Where

op = 2 for port 2, 3 for port 3 o oo = 01 – 16 for output

o abcdef… = hex string to be stored o abcdef - ?, queries current label

Note: When controlling Inline products that also use brackets as delimiters, replace open bracket [with ‘ and closed bracket] with " in the abcde… portion of the command. When this command is sent out the command port the ‘ " will automatically be replaced with [ ].