23

Remote Operation

Communication Protocol

The MSX1616 contains three serial ports for communication. You can configure all three ports to communicate serially via RS-232, RS-422 or RS-485 standards by setting the DIP switches located at the rear of the unit to the appropriate setting.

Use this port...

1

2 and 3

To...

Directly communicate with the switcher.

Control projectors, Inline products, or other serially controlled A/V equipment.

Control Port 1

The baud rate is selectable from 1200 to 38,400. You can change the baud rate using the

$GYDQFHG menu option on the LCD on the front panel or via serial control using the [CPxbpsfd] serial command. Other adjustable parameters for port 1 include flow control (none or Xon/Xoff) and duplex (full or half). Parity, data bits, and stop bits are predefined and have no affect on port

1. The factory default communication parameters for the control port are:

Communication Parameters

Baud rate

Parity

Data bits

Stop bits

Flow control

Duplex

9600

None

8

1

None

Full

Protocol Structure

All commands sent to the unit must contain a leading delimiter, the actual command, and an ending delimiter.

This part of the command string...

Represents:

[

BLANK01

]

The leading character

The actual command.

The ending character

Command

Meaning

[ADDR@]

[BLANK01]

[RES1]

[MS1O02I01]

Remove address from unit

Blank output #1

Enable serial responses

Connect input 1 to output 2 at level 1